Example) ping 192.168.1.112
If you see the “
Reply from
…” message, it means that the server is properly connected.
If you do not see a Reply message, check if the network cable and power cable are properly connected.
2. After successfully connecting he Veilux VPIP-D110X / VPIPI-D110X to IP network
Video movement is slow.
In Basic Setup of Admin Mode, lower the “Quality”. High quality means more data. You can also set the “Max.
Bandwidth” to higher value. But this value must be lower than the maximum upload speed of your network.
For example, if the maximum uploading bandwidth of the network is 400Kbps, set the total “Max. upload rate”
as 384Kbps. If you set it higher, the video image can be corrupted with artifacts.
Ask your network manager or ISP for maximum uploading bandwidth of the network.
The image is dull and I see green, pink dots.
This could be caused by performance limitation of the PC. Do not run too many programs while running viewer
program. The other reason could be missing data while transmission from Veilux VPIP-D110X / VPIPI-D110X.
Mosaic phenomenon.
Mosaic phenomenon occurs when not enough network bandwidth is available considering the resolution and
frame rate of the video.
Example is 704x480 video with low Max. Bandwidth.
Users are recommended to adjust resolution and frame rates to lower values for lower bandwidth network.
3. Additional Trouble Shooting
Problem
Solution
No operating
. Check if the power supply is AC24V.
. Check if RS-485 communication cable is connected correctly.
. Check camera ID setting.
. Check the termination.
No picture
. Check all cable connections.
Dark screen
. Adjust the monitor status.
Abnormal camera
Operation status
. Check if voltage level is out of the specification.
. Check the termination.
Screen not clear
. Check if there is dust on the lens.
. If exposed to excessive light, change the camera angle or location.
. Adjust the lens focus again.