Alarm
Out
Device
Relay1
Power
Supply
(
1
~30
VDC/AC,1A
)
Relay1
+
-
Relay Switch Power Supply
1V~30VDC/AC,1A
Optional
Relay Switch
Alarm
Out
Device
Power
Supply(
30V
~
)
Relay
Fig. 6-5 Connection of Relay to Veilux VPIP-D110X / VPIPI-D110X
6.2. Trouble Shooting
1. After Veilux VPIP-D110X / VPIPI-D110X is successfully installed.
Veilux VPIP-D110X / VPIPI-D110X in viewing mode, neither channel name nor video is display and
eventually timeout message is shown up.
Check the power and network connection of Veilux VPIP-D110X / VPIPI-D110X.
To check if the network is properly operating, open the browser and try to connect to any server.
Example) http://www.yahoo.com
Or open the MS-DOS Prompt and type the following.
ping www.yahoo.com
Then press Enter. If you see the
“Reply
from
…” message it means that the network is working properly.
To check if the Veilux VPIP-D110X / VPIPI-D110X is connected, open the MS-DOS Prompt and type the
following.
ping [the IP of the server]
You can use the supported relay output to directly drive a maximum load of
30V AC/DC at 1A. By connecting additionally relay circuitry (such as optional relay
switch), it can also drive heavier loads.