AC200 Frequency Inverter Maunal
26
F4.34-F4.37
Reserved
0x422
Motor Parameter Group
NO.
Function description
Range of settings and definition
Factory
default
Feature
Address
F5.00
Motor mode
0: Asynchronous motors (AM)
1: Permanent magnet synchronous
motors (PM)
0
×
0x500
F5.01
Number of motor poles
2
~
98
4
〇
0x501
F5.02
Motor rated power
0.1kW
~
1000.0kW
Model set
※
0x502
F5.03
Motor rated frequency
0.01Hz
~
max frequency
Model set
※
0x503
F5.04
Motor rated speed
1rpm
~
65000rpm
Model set
※
0x504
F5.05
Motor rated voltage
1V
~
1500V
Model set
※
0x505
F5.06
Motor rated current
0.1A
~
3000.0A
Model set
※
0x506
F5.07
Asynchronous motor
no-load current
0.1A
~
3000.0A
Model set
※
0x507
F5.08
Asynchronous motor
stator resistance
0.01%
~
50.00%
Model set
※
0x508
F5.09
Asynchronous motor rotor
resistance
0.01%
~
50.00%
Model set
※
0x509
F5.10
Asynchronous motor
stator leakage inductance
0.01%
~
50.00%
Model set
※
0x50A
F5.11
Asynchronous motor
stator inductance
0.1%
~
2000.0%
Model set
※
0x50B
F5.12
synchronous motor stator
resistance
0.01%
~
50.00%
Model set
※
0x50C
F5.13
Synchronous machine d
axis inductance
0.01%
~
200.00%
Model set
※
0x50D
F5.14
Synchronous machine q
axis inductance
0.01%
~
200.00%
Model set
※
0x50E
F5.15
Synchronous machine
back EMF
1V
~
1500V
Model set
※
0x50F
F5.16
Synchronous machine
encoder installation angle
0.0°
~
360.0°
Model set
※
0x510
F5.17-F5.19
Reserved
0x511
F5.20
Motor parameters
self-adjustment selections
0: No operation
1: Rotary type self-study
2: Static type self-study
3: Reserved
0
〇
0x514
F5.21
Synchronous machine
poles searching function
LED “0” digit: closed-loop vector
0: OFF
1: ON
2: On, only operate firstly when
electrify
LED “00” digit: open-loop vector
0010
〇
0x515