AC200 Frequency Inverter Maunal
20
F3.09
AI (VS)upper limit
corresponding setting
0.00%
~
100.00%
100.00%
●
0x309
F3.10
AI filter time
0.00s
~
6.00s
0.010s
●
0x30A
F3.11
AS lower limit
0.00mA
~
20.00mA
4.00mA
●
0x30B
F3.12
AS lower limit
corresponding setting
0.00%
~
100.00%
0.00%
●
0x30C
F3.13
AS upper limit
0.00mA
~
20.00mA
20.00mA
●
0x30D
F3.14
AS upper limit
corresponding setting
0.00%
~
100.00%
100.00%
●
0x30E
F3.15
AS filter time
0.000s
~
6.000s
0.010s
●
0x30F
F3.16
AI used as AS lower limit
0.00mA
~
20.00mA
4.00mA
●
0x310
F3.17
AI ( AS) lower limit
corresponding setting
0.00%
~
100.00%
0.00%
●
0x311
F3.18
AI used as AS lower limit
0.00mA
~
20.00mA
20.00mA
●
0x312
F3.19
AI ( AS) upper limit
corresponding setting
0.00%
~
100.00%
100.00%
●
0x313
F3.20
Vs terminal function
selection (used as X)
See X terminal function
0
〇
0x314
F3.21
VS high level setting
0.00%
~
100.00%
70.00%
●
0x315
F3.22
VS low level setting
0.00%
~
100.00%
30.00%
●
0x316
F3.23
AI terminal function
selection (used as X)
See X terminal function
0
〇
0x317
F3.24
AI high level setting
0.00%
~
100.00%
70.00%
●
0x318
F3.25
AI low level setting
0.00%
~
100.00%
30.00%
●
0x319
F3.26
AS terminal function
selection (as X)
See X terminal function
0
〇
0x31A
F3.27
AS high level setting
0.00%
~
100.00%
70.00%
●
0x31B
F3.28
AS low level setting
0.00%
~
100.00%
30.00%
●
0x31C
F3.29
Valid state setting when
analog used as terminal
0: low level 1: high level
LED 0 digit: VS
LED 00 digit: AI
LED 000 digit: AS
LED 0000 digit: reserved
0000
●
0x31D
F3.30
Analog input curve
selection
LED “0” digit: VS
0: Beeline (default)
1: curve 1
2: curve 2
LED “00” digit: AI (Select voltage or
current input by wire jumper)
LED “000” digit: AS
LED “0000”digit: reserved
0000
●
0x31E
F3.31
Reserved
0x31F
F3.32
Curve 1 lower limit
0.00V
~
10.00V
0.00V
●
0x320