9
M
aintenance and fault recti
fi
cation
9
.
1
M
aintenance
W
hen used as directed in normal operation
,
VEGASCAN
693
is completely maintenance
-
free
.
9
.
2
F
ault recti
fi
cation
VEGASCAN
693
o
ff
ers maximum reliability
.
N
evertheless
faults can occur during operation
.
T
hese may be caused by the
following
,
e
.
g
.:
l
M
easured value of the sensor not correct
l
V
oltage supply
l
I
nterference on the cables
T
he
fi
rst measures to be taken are to check the input
/
output
signals as well as to evaluate the error messages via the
display
.
T
he procedure is described below
.
F
urther compre
-
hensive diagnostics can be carried out on a
PC
with the
software
PACT
ware
™
and the suitable
DTM
.
I
n many cases
,
the causes can be determined in this way and faults can be
recti
fi
ed
.
S
hould the following measures not be successful
,
please call
in urgent cases the
VEGA
service hotline under the phone
number
+
49 1805 858550
.
T
he hotline is available to you
7
days a week round
-
the
-
clock
.
S
ince we o
ff
er this service world
-
wide
,
the support is only
available in the
E
nglish language
.
T
he service is free of
charge
,
only the standard telephone costs will be charged
.
?
E
003
l
CRC
-
error
à
C
arry out a reset
à
R
eturn instrument for repair
?
E
007
l
S
ensor type not compatible
à
S
earch for and allocate sensor under
"
M
eas
.
loop
-
I
nput
"
C
auses of malfunction
F
ault recti
fi
cation
24
hour service hotline
F
ailure messages
M
aintenance and fault recti
fi
cation
VEGASCAN
693
-
15
-
channel
HART
signal conditioning instrument
39
29252
-
EN
-
060513