Vega VEGAPULS 67 Quick Setup Manual Download Page 3

3

1 For your safety

VEGAPULS 67 • Profibus PA

51902-EN-160620

1  For your safety

1.1  Authorised personnel

All operations described in this operating instructions manual must 

be carried out only by trained specialist personnel authorised by the 

plant operator.

During work on and with the device the required personal protective 

equipment must always be worn.

1.2  Appropriate use

VEGAPULS 67 is a sensor for continuous level measurement.

You can find detailed information about the area of application in 

chapter "

Product description

".

Operational reliability is ensured only if the instrument is properly 

used according to the specifications in the operating instructions 

manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device 

beyond that described in the operating instructions manual may be 

carried out only by personnel authorised by the manufacturer. Arbi

-

trary conversions or modifications are explicitly forbidden.

1.3  Warning about incorrect use

Inappropriate or incorrect use of the instrument can give rise to 

application-specific hazards, e.g. vessel overfill or damage to system 

components through incorrect mounting or adjustment.

1.4  General safety instructions

This is a high-tech instrument requiring the strict observance of stand

-

ard regulations and guidelines. The user must take note of the safety 

instructions in this operating instructions manual, the country-specific 

installation standards as well as all prevailing safety regulations and 

accident prevention rules.
Depending on the model, the emitting frequencies of all radar sensors 

are either in the C or K band range. The low transmitting power lies far 

below the internationally permitted limit values. When the instrument 

is used correctly, it presents no danger to human health. It may be 

operated without restriction outside of closed metallic vessels.
The instrument must only be operated in a technically flawless and 

reliable condition. The operator is responsible for trouble-free opera

-

tion of the instrument.

During the entire duration of use, the user is obliged to determine the 

compliance of the necessary occupational safety measures with the 

current valid rules and regulations and also take note of new regula

-

tions.

1.5  Safety label on the instrument

The safety approval markings and safety tips on the device must be 

observed.

Summary of Contents for VEGAPULS 67

Page 1: ...Quick setup guide Radar sensor for continuous level measurement of bulk solids VEGAPULS 67 Profibus PA Document ID 51902...

Page 2: ...cedure 10 4 2 Wiring plan single chamber housing 11 4 3 Wiring plan double chamber housing 11 5 Set up with the display and adjustment module PLICSCOM 5 1 Insert display and adjustment module 12 5 2 S...

Page 3: ...ion specific hazards e g vessel overfill or damage to system components through incorrect mounting or adjustment 1 4 General safety instructions This is a high tech instrument requiring the strict obs...

Page 4: ...tions of VEGAPULS 67 in atmospherically open vessels These applications are not in conformity with the FCC IC approvals of the instrument VEGAPULS 67 is FCC IC approved with all the antenna types de s...

Page 5: ...t is one of our most important duties That is why we have introduced an environment management system with the goal of continuously improving company environmental pro tection The environment manageme...

Page 6: ...the serial number you can access the delivery data of the instru ment via www vega com VEGA Tools and Instrument search You can find the serial number on the inside of the instrument as well as on the...

Page 7: ...g 1 Radar sensor with mounting strap The strap is supplied unassembled and must be screwed to the sen sor before setup with three hexagon socket screws M5x10 and spring washers Max torque see chapter...

Page 8: ...le of inclination Fig 3 Turning by fastening in the centre The compression flange allows mounting on a flange DN 80 ANSI 3 the adapter flange on flanges DN 100 ANSI 4 and DN 150 ANSI 6 You can find dr...

Page 9: ...ng of the radar sensor 3 2 Mounting instructions 1 Distance from the vessel wall 200 mm 200 mm 7 87 Fig 5 Distance of the antenna to the vessel wall socket configuration 2 Keep the socket short round...

Page 10: ...r through the cable entry 6 Lift the opening levers of the terminals with a screwdriver see following illustration 7 Insert the wire ends into the open terminals according to the wir ing plan Fig 6 Co...

Page 11: ...Ex as well as to the Ex ia version I2C Display 1 1 2 5 6 7 8 Fig 7 Wiring plan single chamber housing 1 Voltage supply signal output 4 3 Wiring plan double chamber housing The following illustrations...

Page 12: ...e electronics you can choose any one of four different posi tions each displaced by 90 3 Press the display and adjustment module onto the electronics and turn it to the right until it snaps in 4 Screw...

Page 13: ...djustment 100 00 1 000 m d 2 000 m d Min adjustment 0 00 5 000 m d 4 000 m d 3 Select in the menu item Medium the medium of your applica tion for example Gravel Pebble Medium Bulk solid 4 Select in th...

Page 14: ...early empty If these values are not known an adjustment with other distances for example 10 and 90 is also possible Starting point for these distance specifications is always the seal surface of the t...

Page 15: ...OK Note Check the distance to the product surface because if an incorrect too large value is entered the existing level will be saved as a false signal The level would then no longer be detectable in...

Page 16: ...5 385 m d Meas certainty 3 2 15 dB Sensor status OK Curve selection 3 3 Echo curve Echo curve 3 4 Presentation of the echo curve Service Basic adjustment 4 Display Diagnostics Service Info False signa...

Page 17: ...Profibus PA 51902 EN 160620 Info Basic adjustment 5 Display Diagnostics Service Info Instrument type 5 1 Serial number 12345678 Date of manufacture 5 2 22 November 2010 Software version 3 80 Last chan...

Page 18: ...ntry M20 x 1 5 cable 5 9 mm 1 x blind plug M20 x 1 5 1 x blind plug M16 x 1 5 or optionally available with 1 x plug M12 x 1 for external display and adjustment unit or 1 x closing cap NPT 1 x blind pl...

Page 19: ...19 6 Supplement VEGAPULS 67 Profibus PA 51902 EN 160620 Max number of sensors non Ex Ex 32 10...

Page 20: ...of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change without prior n...

Reviews: