![Vega VEGAPULS 64 Operating Instructions Manual Download Page 77](http://html2.mh-extra.com/html/vega/vegapuls-64/vegapuls-64_operating-instructions-manual_3882860077.webp)
77
11 Supplement
VEGAPULS 64 • 4 … 20 mA/HART - two-wire
51141-EN-160815
Vessel pressure
Vessel pressure
Ʋ Plastic horn antenna
-1 … 2 bar (-100 … 200 kPa/-14.5 … 29.1 psig)
Ʋ Plastic horn antenna - Version with
adapter flange from DN 100 PP or
PP-GF 30
-1 … 1 bar (-100 … 100 kPa/-14.5 … 14.5 psig)
Ʋ Thread with integrated horn antenna -1 … 20 bar (-100 … 2000 kPa/-14.5 … 290.1 psig)
Ʋ Flange with encapsulated antenna
system
-1 … 16 bar (-100 … 2000 kPa/-14.5 … 232.0 psig)
Vessel pressure relating to the flange
nominal pressure stage
see supplementary instructions manual "
Flanges ac-
cording to DIN-EN-ASME-JIS
"
Mechanial stresses
Vibration resistance - Plastic horn antenna
Ʋ With adapter flange
2 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Ʋ with mounting strap
1 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Vibration resistance - Thread with
integrated horn antenna, flange with
encapsulated antenna system
4 g at 5 … 200 Hz according to EN 60068-2-6 (vibration
with resonance)
Shock resistance
100 g, 6 ms according to EN 60068-2-27 (mechanical
shock)
Data on rinsing air connection
Max. permissible pressure
6 bar (87.02 psig)
Air volume, depending on pressure (recommended range)
Plastic horn antenna
Air volume
Pressure
Without reflux valve
With reflux valve
0.2 bar (2.9 psig)
3.3 m
3
/h
-
0.4 bar (5.8 psig)
5 m
3
/h
-
0.6 bar (8.7 psig)
6 m
3
/h
1 m
3
/h
0.8 bar (11.6 psig)
-
2.1 m
3
/h
1 bar (14.5 psig)
-
3 m
3
/h
1.2 bar (17.4 psig)
-
3.5 m
3
/h
1.4 bar (20.3 psig)
-
4.2 m
3
/h
1.6 bar (23.2 psig)
-
4.4 m
3
/h
1.8 bar (20.3 psig)
-
4.8 m
3
/h
2 bar (23.2 psig)
-
5.1 m
3
/h
Connection
Ʋ Thread
G⅛