1
F
unctional safety
1
.
1
I
n general
T
his safety manual applies to measuring systems consisting of
the
VEGAPULS
series
60
radar sensor in two
-
wire and four
-
wire versions
4
…
20
m
A
/
HART
:
VEGAPULS
61
,
62
,
63
,
65
,
66
,
67
,
68
V
alid hardware and software versions
:
S
erial number of the
electronics
S
ensor software
VEGAPULS
61
,
62
,
63
,
65
,
66
>
13978716
from rev
.
3
.
22
VEGAPULS
61
,
62
,
63
with increased sensitiv
-
ity
>
14165303
from rev
.
3
.
25
VEGAPULS
67
,
68
>
14165303
from rev
.
3
.
25
T
he measuring system can be used for level measurement of
liquids and solids which meet the speci
fi
c requirements of the
safety technology
.
T
his is possible up to
SIL
2
in a single channel architecture
(
1
oo
1
D
),
and up to
SIL
3
in a multiple channel
,
diverse
redundant architecture
.
T
he use of the measuring system in a multiple channel
,
homogeneous redundant architecture is excluded
.
T
he
SIL
declaration of conformity can be downloaded from our
homepage in the
I
nternet
.
F
urther abbreviations and terms are stated in
IEC
61508
-
4
.
SIL
S
afety
I
ntegrity
L
evel
HFT
H
ardware
F
ault
T
olerance
SFF
S
afe
F
ailure
F
raction
PFD
avg
average
P
robability of dangerous
F
ailure on
D
emand
PFH
P
robability of a dangerous
F
ailure per
H
our
FMEDA
F
ailure
M
ode
,
E
ff
ects and
D
iagnostics
A
nalysis
λ
sd
R
ate for safe detected failure
λ
su
R
ate for safe undetected failure
S
cope
A
rea of application
SIL
conformity
A
bbreviations
,
terms
VEGAPULS
series
60
-
4
…
20
m
A
/
HART
3
F
unctional safety
31338
-
EN
-
070510
Summary of Contents for VEGAPULS 61
Page 1: ...Safety Manual VEGAPULS series 60 4 20 mA HART Radar...
Page 13: ...VEGAPULS series 60 4 20 mA HART 13 Functional safety 31338 EN 070510...
Page 14: ...14 VEGAPULS series 60 4 20 mA HART Functional safety 31338 EN 070510...
Page 15: ...VEGAPULS series 60 4 20 mA HART 15 Functional safety 31338 EN 070510...