45
13 Supplement
VEGAPOINT 23 • Transistor (PNP/NPN)
56627-EN-210210
Max. torque - process fitting
Ʋ Thread G½, ½ NPT
50 Nm (37 lbf ft)
Ʋ Thread G¾, ¾ NPT
75 Nm (55 lbf ft)
Ʋ Thread G1, 1 NPT
100 Nm (73 lbf ft)
Ʋ Hygienic adapter
20 Nm (15 lbf ft)
Surface quality
R
a
< 0.76 µm (3.00
-5
in)
For following process connections:
Clamp, collar supports
Thread G1 PN25, hygiene design EPDM for hygiene
adapter
Thread G1 PN25, cone 40° for hygiene adapter
Measurement accuracy
Hysteresis
approx. 1 mm (0.04 in)
Switching delay
approx. 500 ms (on/off)
Adjustable: 0.5 … 60 s
Repetitive accuracy
± 1 mm (± 0.04 in)
Ambient conditions
Ambient temperature on the housing
-40 … +70 °C (-40 … +158 °F)
Storage and transport temperature
-40 … +80 °C (-40 … +176 °F)
Relative humidity
20 … 85 %
Mechanical environmental conditions
Sinusoidal oscillations according to EN 60068-2-6 (vibration at resonance)
Ʋ Sensor length ≤ 250 mm (≤ 9.84 in)
4M8 (5 g) at 4 … 200 Hz
Ʋ Sensor length > 250 mm (> 9.84 in)
4M5 (1 g) at 4 … 200 Hz
Impacts
50 g, 2.3 ms according to EN 60068-2-27 (mechanical
shock)
Impact resistance
IK07 acc. to IEC 62262
Process conditions
Process pressure
-1 … 25 bar/-100 … 2500 kPa (-14.5 … 363 psig)
Process temperature
Ʋ With tube length up to max. 250 mm
(9.84 in)
-40 … +115 °C (-40 … +239 °F)
Ʋ For tube length > 250 mm (9.84 in)
-40 … +80 °C (-40 … +176 °F)
SIP process temperature
(SIP = Sterilization in place)
Vapour stratification up to 1 h
+135 °C (+275 F)
Dielectric constant
≥ 1.5