1 For your safety

VEGABAR 86 • Foundation Fieldbus

46323-EN-210430

1  For your safety

1.1  Authorised personnel

All operations described in this documentation must be carried out 

only by trained, qualified personnel authorised by the plant operator.
During work on and with the device, the required personal protective 

equipment must always be worn.

1.2  Appropriate use

Model VEGABAR 86 is a pressure transmitter for level and gauge 

measurement. 
You can find detailed information about the area of application in 

chapter " 

Product description

". 

Operational reliability is ensured only if the instrument is properly 

used according to the specifications in the operating instructions 

manual as well as possible supplementary instructions.

1.3  Warning about incorrect use

Inappropriate or incorrect use of this product can give rise to applica-

tion-specific hazards, e.g. vessel overfill through incorrect mounting 

or adjustment. Damage to property and persons or environmental 

contamination can result. Also, the protective characteristics of the 

instrument can be impaired.

1.4  General safety instructions

This is a state-of-the-art instrument complying with all prevailing 

regulations and directives. The instrument must only be operated in a 

technically flawless and reliable condition. The operator is responsi-

ble for the trouble-free operation of the instrument. When measuring 

aggressive or corrosive media that can cause a dangerous situation 

if the instrument malfunctions, the operator has to implement suitable 

measures to make sure the instrument is functioning properly.
The safety instructions in this operating instructions manual, the na-

tional installation standards as well as the valid safety regulations and 

accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device 

beyond that described in the operating instructions manual may be 

carried out only by personnel authorised by the manufacturer. Arbi-

trary conversions or modifications are explicitly forbidden. For safety 

reasons, only the accessory specified by the manufacturer must be 

used.
To avoid any danger, the safety approval markings and safety tips on 

the device must also be observed.

1.5  EU conformity

The device fulfils the legal requirements of the applicable EU direc-

tives. By affixing the CE marking, we confirm the conformity of the 

instrument with these directives.

Summary of Contents for VEGABAR 86

Page 1: ...Quick setup guide Submersible pressure transmitter with ceramic measuring cell VEGABAR 86 Foundation Fieldbus Document ID 46323...

Page 2: ...ment module 11 5 1 Insert display and adjustment module 11 5 2 Parameter adjustment Quick setup 12 5 3 Parameter adjustment Extended adjustment 14 5 4 Menu overview 15 6 Set up with smartphone tablet...

Page 3: ...s is a state of the art instrument complying with all prevailing regulations and directives The instrument must only be operated in a technically flawless and reliable condition The operator is respon...

Page 4: ...equipment NE 53 Compatibility of field devices and display adjustment components NE 107 Self monitoring and diagnosis of field devices For further information see www namur de 1 7 Environmental instr...

Page 5: ...ment With it you can find the following instrument data on our homepage Product code HTML Delivery date HTML Order specific instrument features HTML Operating instructions and quick setup guide at the...

Page 6: ...or heated vessels Note Make sure that during installation or maintenance no moisture or dirt can get inside the instrument To maintain the housing protection make sure that the housing lid is closed...

Page 7: ...7 3 Mounting VEGABAR 86 Foundation Fieldbus 46323 EN 210430 Instruments in protection IP66 IP68 1 bar ventilation via capillar ies in non detachable cable Instruments with absolute pressure...

Page 8: ...n nut of the cable gland and remove blind plug 4 Remove approx 10 cm 4 in of the cable mantle strip approx 1 cm 0 4 in of insulation from the ends of the individual wires 5 Insert the cable into the s...

Page 9: ...le chamber housing 1 Voltage supply signal output 2 Contact pins for the display and adjustment module or interface adapter 3 Simulation switch 1 mode for simulation release 4 For external display and...

Page 10: ...s 5 1 2 6 7 8 2 3 4 1 Fig 6 Connection compartment double chamber housing 1 Voltage supply signal output 2 For display and adjustment module or interface adapter 3 For external display and adjustment...

Page 11: ...d by 90 It is not necessary to interrupt the power supply Proceed as follows 1 Unscrew the housing lid 2 Place the display and adjustment module on the electronics in the desired position and turn it...

Page 12: ...asily adapt the sensor to the application select the menu item Quick setup in the start graphic on the display and adjustment module Carry out the following steps in the below sequence You can find Ex...

Page 13: ...the instrument offset on the measured value Max adjustment In this menu item you carry out the max adjustment for level Enter the percentage value and the corresponding value for the max level Min adj...

Page 14: ...he real product level during the adjustment is not important because the min max adjustment is always carried out without changing the product level These settings can be made ahead of time without th...

Page 15: ...nu points are available The submenu points are described below 5 4 Menu overview The following tables show the adjustment menu of the instrument Depending on the instrument version or application all...

Page 16: ...ure Actual measuring cell and electronic tem perature Simulation Pressure percent current output linearized percent measuring cell tem perature electronics temperature Process pressure Additional adju...

Page 17: ...te Bluetooth 1 Switch On Bluetooth active Off Bluetooth not active The security concept of Bluetooth operation absolutely requires that the default setting of the sensor PIN be changed This prevents u...

Page 18: ...lect the device search via Bluetooth and start the search function The device auto matically searches for Bluetooth capable devices in the vicinity The message Instrument search running is displayed A...

Page 19: ...19 6 Set up with smartphone tablet PC notebook via Bluetooth VEGABAR 86 Foundation Fieldbus 46323 EN 210430 Fig 11 Example of an app view Setup sensor adjustment App view...

Page 20: ...ata version IP66 IP67 and IP66 IP68 0 2 bar 1 Options of the cable entry Cable entry M20 x 1 5 NPT Cable gland M20 x 1 5 NPT cable see below table Blind plug M20 x 1 5 NPT Closing cap NPT Material cab...

Page 21: ...21 Notes VEGABAR 86 Foundation Fieldbus 46323 EN 210430...

Page 22: ...22 Notes VEGABAR 86 Foundation Fieldbus 46323 EN 210430...

Page 23: ...23 Notes VEGABAR 86 Foundation Fieldbus 46323 EN 210430...

Page 24: ...ing scope of delivery application practical use and operat ing conditions of the sensors and processing systems correspond to the information available at the time of printing Subject to change withou...

Reviews: