40
13 Supplement
VEGABAR 29 • Two-wire 4 … 20 mA
57087-EN-210301
Nominal range
Overload capacity, max. pressure Overload capacity, min. pressure
0 … 2.5 bar/0 … 250 kPa
+10 bar/+1000 kPa
0 bar abs.
0 … 5 bar/0 … 500 kPa
+20 bar/+2000 kPa
0 bar abs.
0 … 10 bar/0 … 1000 kPa
+40 bar/+4000 kPa
0 bar abs.
0 … 25 bar/0 … 2500 kPa
+120 bar/+12 MPa
0 bar abs.
Nominal measuring ranges and overload capacity in psi
Nominal range
Overload capacity, max. pressure Overload capacity, min. pressure
Gauge pressure
0 … +5 psig
+60 psig
-14.5 psig
0 … +15 psig
+60 psig
-14.5 psig
0 … +30 psig
+145 psig
-14.5 psig
0 … +75 psig
+290 psig
-14.5 psig
0 … +150 psig
+580 psig
-14.5 psig
0 … +300 psig
+1740 psig
-14.5 psig
0 … +900 psig
+4350 psig
-14.5 psig
0 … +1450 psig
+4350 psig
-14.5 psig
0 … +3000 psig
+7250 psig
-14.5 psig
0 … +9000 psig
+17400 psig
-14.5 psig
0 … +15000 psig
+29000 psig
-14.5 psig
-3 … +3 psig
+60 psig
-14.5 psig
-7 … +7 psig
+60 psig
-14.5 psig
-14.5 … 0 psig
+60 psig
-14.5 psig
Absolute pressure
0 … +15 psi
+43 psi
0 psi
0 … +30 psi
+145 psi
0 psi
0 … +75 psi
+290 psi
0 psi
0 … +150 psi
+580 psi
0 psi
0 … +300 psi
+1740 psi
0 psi
Adjustment ranges
Specifications refer to the nominal measuring range, pressure values lower than -1 bar cannot be
set
Zero/Span adjustment:
Ʋ
Zero
-20 … +95 %
Ʋ
Span
-120 … +120 %
Maximum permissible Turn Down
Unlimited (recommended 20 : 1)