![Vega VEGABAR 28 Operating Instructions Manual Download Page 47](http://html1.mh-extra.com/html/vega/vegabar-28/vegabar-28_operating-instructions-manual_859551047.webp)
47
13 Supplement
VEGABAR 28 • Three-wire 1 x transistor or 4 … 20 mA
57534-EN-220826
1
2
0 °C
(32 °F)
40 °C
(104 °F)
70 °C
(158 °F)
130 °C
(266 °F)
110 °C
(230 °F)
Fig. 29: Temperature derating VEGABAR 28
1 Process temperature
2 Ambient temperature
1
2
0 °C
(32 °F)
40 °C
(104 °F)
70 °C
(158 °F)
100 °C
(212 °F)
90 °C
(194 °F)
Fig. 30: Temperature derating VEGABAR 28, with activated Bluetooth communication
1 Process temperature
2 Ambient temperature
SIP process temperature
11)
Device configuration suitable for vapour, i.e. measuring cell seal EPDM or FFKM (Perlast G74S),
previous CIP cleaning up to max. +80 °C (+176 °F):
12)
SIP process temperature with vapour stratification up to
Ʋ 15 minutes
+150 °C (+302 °F)
Ʋ 30 minutes
+140 °C (+284 °F)
Ʋ 1 hour
+135 °C (+275 °F)
Process pressure
Permissible process pressure
see specification "
MWP
" on the type label
13)
Indication
Status indication
LED illuminated ring (green-yellow-red)
Adjustment
PC/Notebook
PACTware/DTM
Smartphone/Tablet
Adjustment app
Bluetooth interface
Bluetooth standard
Bluetooth 5.0
11) SIP = Sterilization in place
12) CIP = Cleaning in place
13) MWP: Maximum Working Pressure