12. While speaking into each of the

BP-700 headset mics, select the
corresponding monitor "

MON

"

switch on the MS-700 front
panel. Observe the bar-graph
LED's on the left side of the
MS-700 front panel. The "-2"
LED should illuminate often on
voice peaks, but the "+3" LED
should illuminate only rarely.

13. If necessary, adjust the

microphone gain for the
BP-700 via the screwdriver
adjustment access hole on the
side of the unit closest to the
"D" pushbutton. This is the top
adjustment to the right of the
XLR connector and to the left
of the "D" pushbutton.

14. If applicable, connect the wired

intercom system to the rear
panel of the MS-700. Two
intercom channels can be
accommodated at the same
time. For standard Clear-Com
intercom lines, connect line one
to the IC1/IC2 XLR connector,
and line two to the IC2
connector. For "TW" and RTS
systems, both channels are on
the same connector, which
should be plugged into
"IC1/IC2".

15. Select "Clear-Com" on the rear

panel (Clear-Com – TW/RTS
pushbutton "in") for standard
Clear-Com lines, or "TW/RTS"
for Clear-Com two-wire or RTS
intercom lines (pushbutton
"out").

16. On the MS-700 front panel,

select one or both intercom
channels via the "on"
pushbuttons in the intercom
area on the panel. The
incoming signal can be
monitored by selecting the
appropriate monitor "

MON

"

pushbutton and observing the
bar-graph LED's as described
above.

17. Adjust the intercom input and

output levels for the intercom
lines as necessary with the
front panel "in" and "out"
trimmers. If the "null" control
requires adjustment, see
page 14 “Operational Features.”

18. If applicable, connect balanced

line-level program audio or IFB
audio to the "PROG" XLR
connector on the MS-700 rear
panel. Monitor and adjust level
with the corresponding
controls on the front panel of
the unit.

Tx mic gain
adjustment

Rx squelch

sensitivity

Summary of Contents for Q700

Page 1: ...Q700 Wireless Intercom System Owner s Manual revision 3 41 August 1 2001...

Page 2: ...ge 7 7 Move the BP 700 beltpacks at least 6 feet 2 M away from the MS 700 and separate them from each other by at least 10 inches 40 cm Momentarily depress the A pushbutton 8 Observe the RF LED s on t...

Page 3: ...to the IC2 connector For TW and RTS systems both channels are on the same connector which should be plugged into IC1 IC2 15 Select Clear Com on the rear panel Clear Com TW RTS pushbutton in for standa...

Page 4: ...est quality and performance Vega has been the leader in wireless intercom systems for well over a decade This experience insures you of a Vega Intercom System of quality performance and reliability Un...

Page 5: ...audio circuitry in the MS 700 MON When selected as indicated by the associated LED routes a sample of the receiver audio to the monitor amplifier and bar graph The audio may be monitored whether on no...

Page 6: ...power output to 250 mW maximum Clear Com TW Switch In the depressed position configures the two intercom interfaces to be compatible with the Clear Com standard In this mode intercom channel 1 is con...

Page 7: ...in order to program the BP 700 beltpacks replacement cables may be purchased at an electronics store To program one of the master station receivers or the master station transmitter set the function s...

Page 8: ...ower to both units is on and check all connections If you connected the serial cable to Com Port 2 go to Com Port in the menu bar and select Com Port 2 Master Station Frequency Setup Click Master Stat...

Page 9: ...5 for each corresponding beltpack Locking the Master Station Control Panel The Q700 application software allows you to lock the front panel switches on the MS 700 master station thereby preventing cha...

Page 10: ...ree times to indicate that you are back in the top level programming mode Level 1 If no button is pushed for 10 seconds the LED s will flash three times once again This is repeated every 10 seconds un...

Page 11: ...n of the preset defaults After a pause all four LED s will triple flash to indicate return to top level programming mode Level 1 If no button is pushed for 10 seconds the LED s will flash three times...

Page 12: ...ssignment A D mode and action type the graphic changes to reflect the settings To set the microphone type select either Dynamic or Electret 2 Click the program button to apply the new settings to the...

Page 13: ...the memory problem for NiCad batteries This is one of the reasons that NiCads are not recommended Mistakenly recharging alkaline cells can cause overheating battery venting and even fire To help avoi...

Page 14: ...ter will the modes interact Operational Features MS 700 Intercom Interfaces The MS 700 master station will interface with two intercom lines simultaneously as well as accommodate both four wire inputs...

Page 15: ...f the MS 700 reaches about 105 degrees F 41 deg C the fan will begin to rotate at low speed If the internal temperature continues to rise the fan will reach full RPM when the internal temperature reac...

Page 16: ...ction switches monitor level ac power switch transmit power switch and additional controls Indicators Signal present mode beltpack low battery warning select status and monitor status for each receive...

Reviews: