M-BUS-2 / User Manual  

 

13

 

Revision 07 - 14 September 2020

 

 

4 VEGA LORAWAN CONFIGURATOR 

The "Vega LoRaWAN Configurator"  application  (hereinafter referred to as the 

configurator) is intended for setting up the device via USB. 

The configurator has two modes of operation -  "Simple" and "Expert". In the "Simple" 

mode, only basic settings are available. In the "Expert" mode, the basic settings, advanced 
settings and the ability to check the coverage area of the signal from the gateways are available. 
Next, the work of the application is considered in the “Expert” mode. 

INTERFACE OF THE APPLICATION 

The "Vega LoRaWAN Configurator" application does not require the special installation. 

When the executable file is launched, the window for working with the application appears. 

 

The menu on the left allows you to switch between the “Simple” and “Expert” modes, 

select the device model, connect to the device or disconnect from it, get and apply settings. 

Summary of Contents for M-BUS-2

Page 1: ...www vega absolute ru LORAWAN CONVERTER M BUS 2 User Manual...

Page 2: ...mode is not supported minor changes 03 10 08 2018 KEV Changes in the device logic frequency plans are added changes in the communication protocol in technical characteristics new supported meters are...

Page 3: ...ation in the independent poll mode of the metering devices 10 Connecting via USB 11 4 VEGA LORAWAN CONFIGURATOR 13 Interface of the application 13 Connection to the device 14 Device info tab 15 LoRaWA...

Page 4: ...provide the stable radio between the gateway and the end device it is recommend avoiding the device installation in the places which are barriers for the radio signal getting through like a reinforce...

Page 5: ...one model counting devices to one converter If you simultaneously use different models of metering devices with a single converter the correct functioning of the converter is not guaranteed COMUNICAT...

Page 6: ...ONAL M BUS 2 converter is A class device LoRaWAN classification and has the following features o ADR support Adaptive Data Rate o Sending of confirmed packets configurable o Temperature measurement by...

Page 7: ...ABP or OTAA Communication period 5 15 30 minutes 1 6 12 or 24 hours Data collection period 5 15 30 minutes 1 6 12 or 24 hours Memory amount for storing packets 50 packets Antenna connector SMA Sensiti...

Page 8: ...e the physical level of the M BUS interface is switch on supply voltage is applied to the outputs MBAS MBAS just before meter polling with a programmable delay the delay value is depends on the type o...

Page 9: ...ou need to connect the battery to the one of the two power connectors on the board The converter supports two activation methods in the LoRaWAN network ABP and OTAA Select one of the methods using Veg...

Page 10: ...start button more than 5 seconds Before connecting the device to the network make sure that its registration data is entered in the network Device EUI Application EUI and Application Key for OTAA or D...

Page 11: ...tor application while converter connected to a computer CONNECTING VIA USB The device M BUS 2 adjusted with the Vega LoRaWAN Configurator application See part 4 Before connecting the device to the com...

Page 12: ...window you need to click Next then Install and then the installation will begin When the installation is completed successfully the following screen appears After pressing Finish the driver is ready f...

Page 13: ...c settings advanced settings and the ability to check the coverage area of the signal from the gateways are available Next the work of the application is considered in the Expert mode INTERFACE OF THE...

Page 14: ...Vega LoRaWAN Configurator application 3 Click the Connect button in the menu on the left The application automatically recognizes the device model and the device selection menu becomes inactive To re...

Page 15: ...r The Air Activation is displayed Key management not displayed in the Simple mode allows you to change the factory keys to register the device on the network and reset the keys back to the factory set...

Page 16: ...s already connected to the network reconnection procedure will occur Link check not displayed in the Simple mode when pressed the device sends a special signal to the LoRaWAN network in response to wh...

Page 17: ...868 5 MultiSF 125 kHz RX2 869 525 SF12 125 kHz RU 868 1 868 9 MultiSF 125 kHz 2 869 1 MultiSF 125 kHz RX2 869 1 MultiSF 125 kHz Custom Set with Vega LoRaWAN Configurator application In the EU_868 and...

Page 18: ...considered empty Activation type selecting ABP or OTAA device activation method Confirmed uplinks when you choose confirmed the device will retry sending the packet until it receives the server confir...

Page 19: ...first receiving window opening The second receiving window always opens after 1 second after the first Join accept delay 1 not displayed in the Simple mode sets the time that the device will open the...

Page 20: ...until it receives a confirmation or until it sends as many packets as specified in this option TX power not displayed in the Simple mode the device RF transmitter power is adjusted to this value when...

Page 21: ...dresses for poll of the connected devices The secondary address usually is equal to meter serial number Data transmission settings a group of parameters that allows you to configure the collection and...

Page 22: ...ransmissions device completes the communication session until the next one according to the schedule In this case the device continues to collect data according to the data collection period and store...

Page 23: ...ture 100 uint16 2 bytes Current temperature in the return line 100 uint16 2 bytes Current flow of coolant l h uint16 The converter has internal clock and calendar time and date is factory set When sen...

Page 24: ...em at a moment of the packet transmission unixtime UTC uint16 After receiving this type of package the application can send to modem the packet with time correction 3 Settings packet transmitting on L...

Page 25: ...device Size in bytes Field description Data type 1 byte Packet type this packet 00 uint8 2 bytes ID of parameter uint16 1 byte Data length len uint8 len bytes Parameter value 2 bytes ID of parameter u...

Page 26: ...0 device type not set 1 Teplouchet 1 2 STE 21 Berill 3 Danfoss Sonometer_500 4 ELF_M 5 Weser 6 MULTICAL_801 7 MULTICAL_402 8 LANDIS_GYR_COMMON 9 SHARKY_775 10 PULSAR 49 Data collection period 1 byte...

Page 27: ...ON REQUIREMENTS The M BUS 2 converter shall be stored in the original packaging in heated room at temperatures 5 to 40 and relative humidity less than 85 The converter shall be transported in covered...

Page 28: ...US 2 User Manual 28 Revision 07 14 September 2020 7 CONTENT OF THE PACKAGE The M BUS 2 device is delivered complete with Converter M BUS 2 1 pc Antenna LoRa 1 pc 24 pin bus 1 pc Factory certificate 1...

Page 29: ...pecified in this user manual Warranty does not apply to power supplies of devices sending more than 20 000 packets the device with mechanical electrical and or other damages and defects caused by viol...

Page 30: ...M BUS 2 User Manual 30 Revision 07 14 September 2020 vega absolute ru Operation Manual Vega Absolute OOO 2017 2020...