15
4 Connecting to power supply
FIBERTRAC 31 • Four-wire 4 … 20 mA/HART
62067-EN-211203
4.2 Connection - Level measurement
Non-Ex instruments and instruments with non-intrinsically safe
current output
1
1
24
/L
/N
PE
56
91
01
1
22
11
12
21
22
19
20
18
17
14
13
16
15
12
2
7
3
1
4
5
6
8
9
10
Fig. 8: Electronics and connection compartment with non-Ex instruments and
instruments with non-intrinsically safe current output
1 Voltage supply
2 Relay output
3 Signal output 4 … 20 mA/HART active
4 Signal output 4 … 20 mA/HART passive
5 Signal input 4 … 20 mA
6 Switching input for NPN transistor
7 Switching input floating
8 Transistor output
9 Interface for sensor-sensor communication (MGC)
10 Setting the bus address for sensor-sensor communication (MGC)
1)
5 6 7 8
2
1
Fig. 9: Adjustment and connection compartment with non-Ex instruments and
instruments with non-intrinsically safe current output
1 Terminals for the external display and adjustment unit
2 Contact pins for the display and adjustment module or interface adapter
Instruments with intrinsically safe current output
You can find detailed information on the explosion-protected versions
(Ex-ia, Ex-d) in the Ex-specific safety instructions. These safety
Electronics and con-
nection compartment
- Non-Ex instruments and
instruments with non-
intrinsically safe current
output
Adjustment and con-
nection compartment
- Non-Ex instruments and
instruments with non-
intrinsically safe current
output
1)
MGC = Multi Gauge Communication