ECBU Configuration Database
The ECBU configuration database can be modified via the Veethree Display. The default configuration
for each of the 12 ECBs is set as follows:
Parameter
Valid Values
Default Value
Comments
Programmed Rating
2 - 20 A
2
Power-Up Default State
Last State (prior to Power Down)
Off
On
Last State
Switch Control
Digital (CAN)
Discrete Input
Analog Input
Digital (CAN)
Assigned Discrete Input
(DI)/Analog Input (AI)
0 - 12
0
ECB State when DI/AI
Active
Off
On
Off
PWM Enable
Disabled
Enabled
Disabled
AI Trigger Point
0 - 12V
0
AI Release Point
0 - 12V
0
ECB String #1
18 ASCII characters
ECB #
ECB String #2
10 ASCII characters
<Blank>
ECB String #3
10 ASCII characters
<Blank>
ECB String #4
10 ASCII characters
<Blank>
Reversible Motor
False
True
False
Channels 9-10, 11-12 support
Reversible Motor
Inhibit Fail Short
Not Inhibited
Inhibited
Not Inhibited
Soft Start Enable
Disabled
Enabled
Disabled
Soft Ramp Time
0 - 255
0
0.1 Seconds
Soft Stop Enable
Disabled
Enabled
Disabled
Coordinated ECB Role
Primary
Secondary
Primary
Coordinated ECB Trip
Trip independently
Trip as a set
Trip
independently
Trip as a set is only valid for ECBs
configured as Secondary
Sequencer Control Enable
Disabled
On-Stay Off
On-Off-Repeat
Disabled
Sequencer Offset
0 - 255
0
Not set by the Display
Sequencer
–
Time On
0 - 255
0
Minutes
Sequencer
–
Time Off
0 - 255
0
Minutes