VEETHREE M2 CONNECTION DATA
The Veethree M2 display interfaces to data via the Deutsch DT04-6P con-
nector on the rear of the display - wired as shown (see pin out diagram).
1
2
3
4
5
6
1
2
3
4
5
6
Power (-)
Power (+)
CAN H
CAN L
Alarm
Output
AN
Analog Input
Ground and power (10-32VDC)
Supply should be protected by
500mA-rated circuit breaker/fuse
Low Side Relay Switch to Ground
Primary CAN Data Low
Primary CAN Data High