Installation
Retrofit Procedure
26
TO REPLACE A FAULTY VAPORTEK PUMP:
•
VaporTEK-3 Controller Board Kit P/N 900895-001
•
VaporTEK Pump
SITE PREPARATION
•
Before opening the pump, switch off, tag and lock out the main switch/breaker at the main distribution board so
that they cannot be switched back on.
•
Please make sure, that the area around the dispenser is blocked for customers.
•
Remove all panels from the dispenser and take care for good ventilation. For further information see installation
manual.
•
Look for leakage. Possible fuels on ground must be removed.
Retrofit Procedure
VaporTEK-3 Controller Board Replacement
1.
Replace the old VaporTEK Controller and housing and with the new VaporTEK-3 Controller and housing
following the steps in “VaporTEK-3 Controller and VaporTEK Pulse Interface Installation” on page 21.
2.
Connect the P/N 900899-001 adapter cable’s screw terminal plug to the pump motor power cable screw
terminal plug. Connect the 4-pin snap plug end of the motor power adapter cable to the Motor Power
connector on the VaporTEK-3 Controller board (Item 3 in Figure 9).
3.
Attach the adapter cable’s Motor Power plug ground wire to the PE terminal on the VaporTEK-3 Controller
board (Item 6, Figure 9).
4.
Connect the P/N 900898-001 adapter cable’s screw terminal plug to the pump control cable screw terminal
plug. Connect the 6-pin snap plug end of the motor control adapter cable to the Motor Signal connector on
the VaporTEK-3 Controller board (Item 4 in Figure 9).
VaporTEK-3 Controller Board/New VaporTEK Pump Replacement
1.
Remove the old VaporTEK pump and replace it with the new one.
2.
Replace the existing VaporTEK Controller and housing and with the new VaporTEK-3 Controller board and
housing following the steps in “VaporTEK-3 Controller and VaporTEK Pulse Interface Installation” on page 21.
OFF