VaporTEK Calibration
Gas Meter Calibration
47
2.
When the display below appears, press the keys shown:
3.
When display below appears, press the key shown:
4.
Match the calibration factor on the gas meter (see Figure 24) with the following display on the FB1 Terminal. If
the calibration factor already matches, press ‘
ENTER
‘. If not, press ‘
F2
‘ to change the calibration factor.
5.
When display below appears, input the calibration factor shown on the gas meter (example: 07 is now the
New factor) and press ‘
ENTER
’.
Refer to the Burkert Gas meter product manual for the calibration factor. It is typically marked “K-Factor” (see
Figure 24).
Figure 24. Locate the Burkert Gas Meter Calibration Factor
*** SERVICE ***
Gas
m
easu
r
i
ng
(1)
SYS–Ide
n
tify (2)
EC2000 (3)
VAPOR CONTROLLER
* Gas
m
easu
r
i
ng
*
Tot : 000,0 lite
r
Cu
r
: 000,0 l/
m
i
n
F5
* Gas
m
ete
r
**
Calib. facto
r
Cu
r
: 05
Cha
ng
e with F2
F2
* Gas
m
ete
r
**
Calib. facto
r
Cu
r
: 05
New : 07
ENTER
7
Kal Faktor
7