Introduction

Restricting System Programming Access

2

-

If Printer was selected in Communication Setup Type

, the operator can print the Tank Status Report and 

Inventory Report, and Setup Report and Diagnostic Report (if enabled). Note, the Diagnostic Report is only 
for system troubleshooting and is not discussed in this manual. See the TLS-50 Site Prep Manual for a de-
scription of this report.

-

If Modem was selected in Communication Setup Type

, during the initialization sequence an auto-answer 

command will be transmitted to the modem. 

-

If either Modem or Serial was selected in Communication Setup Type

, the user may use a serial lan-

guage different from the local language (the serial language selections will be languages that map to the stan-
dard ASCII character set).

Restricting System Programming Access

To protect against unauthorized access to system operation, two security features can be enabled.

SYSTEM SECURITY

A switch in the console can be set to prevent access to the setup and diagnostic menus after initial programming.

SERIAL SECURITY

A switch in the console can be set that requires the operator to enter a 6-digit security code before the system will 
respond to a serial command (models with Serial Package option only). The default serial security code is 000000. 
The security code itself can be changed with a serial command. However, the serial security code switch must be 
reset to the Open position to inhibit the security code requirement.

Summary of Contents for TLS-50 Series

Page 1: ...Manual No 577013 892 Revision A Quick Help TLS 50 Console...

Page 2: ...s contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this publication The information contained in this publication may be subject to c...

Page 3: ...options are available 1 Alarm package includes product level alarms and an overfill alarm activated relay output 2 Alarm and Serial package includes the Alarm package and an optional serial interface...

Page 4: ...n guage different from the local language the serial language selections will be languages that map to the stan dard ASCII character set Restricting System Programming Access To protect against unauth...

Page 5: ...s activated an audible beeper inside the console is also switched on Figure 2 Front Panel Controls LEGEND FOR NUMBERED BOXES IN Figure 2 1 Bi Color LED Green Continuously On Normal Red Flashing Alarm...

Page 6: ...r key press to scroll to the first display in the submenu of the current item If the current item does not have a submenu there is no response Back key press to scroll back to the previous display in...

Page 7: ...arm condition returns to the normal state the alarm will be removed from the list of alarms If no alarms are active the LED will return to the Normal state continuous green the beeper will be switched...

Page 8: ...required Stop bit set to 1 recommended and Handshake set to XON XOFF may be required at the higher baud rates Note for printing to occur the TLS 50 and printer communications settings must match Inven...

Page 9: ...For technical support sales or other assistance please visit www veeder com...

Reviews: