A-1
Appendix A: ANZEx Conditions of Certification
ANZEx CONDITIONS OF CERTIFICATION:
ANZEx 04.3005X
1. It is a condition of manufacture that each motor be subjected to the routine high voltage test of clause 6.2 of
AS2380.1.
2. It is a condition of safe use that all submerged turbine pumps, manifolds and associated equipment be installed
in accordance with the manufacturer’s Installation, Operation and Service Manuals supplied.
3. It is a condition of safe use that all installations must provide reliable electrical connection between the pump
motor, frame, pipe, manifold or junction box and the tank structure for both electrical protection and
equipotential bonding.
4. It is a condition of safe use that, where terminal boxes are used for termination of the cables from the motor and
the supply source, they shall be Australian certified for use in Gas Group IIA and Zone I hazardous areas.
5. It is a condition of safe use that where a differential pressure switch or transducer is installed, each must be
capable of ensuring that the nominated temperature classification is not exceeded.