Veeder-Root C342 Series Technical Manual Download Page 4

4

1675 N. Delany Road

Gurnee, IL 60031–1282

Phone: 847.662.2666

Fax: 847.662.6633

Danaher Controls

G E N E R A L

Printed in U.S.A.
#702085-0001
February 13, 1997
Revision none

SPECIFICATIONS

Count /Time Input:

Count Input: NPN or PNP Signal field selectable
Count Speed:  30 Hz or 7.5 kHz max
Logic:  Low < 0.7 VDC, High > 5 VDC
Minimum Pulse Width:  70 

µ

second

Maximum Input: 30 VDC

Quadrature Input (C342-8562 only):

Type:  Line driver or square wave pulse (A leading B for up

counting)

Count Speed:  2 kHz

Physical:

Dimensions:  24mm x 48mm, 32mm deep
Mounting: Panel Mount (mounting bracket supplied)

22mm (+ 0.3mm) x 45mm (+ 0.6mm) panel cutout

Maximum Panel Thickness:  26mm
Connections:  6 screw terminals
Weight:  Approximately 2.25 ounces
Front Panel Rating:  IEC IP65

Reset Input:

Type: NPN Signal, Contact Closure
Minimum Pulse Width:  15 ms

Gate Input:

Type:  NPN Signal, Contact Closure

Output: (C342-0562, C342-1562, C342-2562):

Type:  PNP transistor
Voltage/Curent:  Supply less 2 Volt drop, 10 mA max

Operation:

Power Supply: 12 - 24 VDC (+20%/-10%)
Power Consumption:  <150 mA
Display Type:  6 digit LED
Display Height:  7.6 mm
Data Retention:  Non volatile RAM > 10 years
Factory Programmable Settings:  Setpoint, Prescale Value,

Decimal Position, Text Message

Operating Temperature:  -10

°

C to 50

°

C

Storage Temperature:  -20

°

C to 60

°

C

Approvals:  CE Mark

ORDERING INFORMATION

Part #

Description

C342-0562

Count Totalizer

C342-0562-A

As above with factory programmed value*

C342-1562

Timer (H:M:S)

C342-1562-A

As above with factory programmed value*

C342-3464

Tachometer

Part #

Description

C342-2562

Timer (Hundreths of Hours)

C342-2562-A

As above with factory programmed value*

C342-3562

Tachometer

C342-4562

Message Display

C342-8562

Position Indicator

* Possible Factory Programmable Settings:  Setpoint, Prescale
Value, Decimal Position, Text Message. Specifcy the setting
and value when placing an order. (Ex:  Setpoint = 4567)

Standard  products manufactured by the Company are warranted
to be free from defects in workmanship and material for a period
of one year from the date of shipment, and products which are
defective in workmanship or material will be repaired or replaced,
at the option of the Company, at no charge to the Buyer.  Final
determination as to whether a product is actually defective rests
with the Company.  The obligation of the Company hereunder
shall be limited solely to repair and replacement of products that
fall within the foregoing limitations, and shall be conditioned
upon receipt by the Company of written notice of any alleged
defects or deficiency promptly after discovery within the warranty
period, and in the case of components or units purchased by the
Company, the obligation of the Company shall not exceed the
settlement that the Company is able to obtain from the supplier
thereof. No products shall be returned to the Company without its

prior consent.  Products which the Company consents to have returned
shall be shipped F.O.B. the Company's  factory.  The Company cannot
assume responsibility or accept invoices for unauthorized repairs to its
components, even though defective.  The life of the products of the
Company depends, to a large extent, upon the type of usage thereof,
and THE COMPANY  MAKES NO WARRANTY AS TO FITNESS OF ITS
PRODUCTS FOR  SPECIFIC APPLICATIONS BY THE BUYER NOR AS
TO PERIOD OF SERVICE UNLESS THE COMPANY SPECIFICALLY
AGREES OTHERWISE IN WRITING AFTER THE PROPOSED USAGE
HAS BEEN MADE KNOWN TO IT.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL
OTHER WARRANTIES EXPRESSED OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR OF
FITNESS FOR A PARTICULAR PURPOSE.

WARRANTY

Summary of Contents for C342 Series

Page 1: ...tory programmable features Setpoint Scale Value Decimal Position Text Message IEC IP65 rated front panel for use in washdown environments Index Overview Installation page 2 Terminal Connections page 2 Setup Front Panel Operation page 3 Programming page 3 General Specifications page 4 Ordering Information page 4 Warranty page 4 Models Covered in this Manual C342 0464 Totalizer Accumulates and displ...

Page 2: ...nals are accumu lated for count and tachometer versions For timer versions the timerrunswhencontactisclosed See Programming to select low speed NPN mode Channel B Wiring Insert wire into the appropriate openings as pictured in the drawing below Turn the screws located on the rear of the terminal block to tighten the clamp and secure the wire Solid State Output When the factory programmed preset va...

Page 3: ... down the the FRP key for seconds to select it Scroll between the two Front Panel Enable choices by brief press and release of the FPR key Hold the FPR key for 2 sconds to select the desired choice and return to Operating Mode Note The NPN PNP selection applies to the Signal Reset and Hold inputs PROGRAMMING During Power up C342 0562 Totalizer The instrument will accumulate and display the pulses ...

Page 4: ...y Programmable Settings Setpoint Prescale Value Decimal Position Text Message Specifcy the setting and value when placing an order Ex Setpoint 4567 Standard products manufactured by the Company are warranted to be free from defects in workmanship and material for a period of one year from the date of shipment and products which are defective in workmanship or material will be repaired or replaced ...