O V E R V I E W

INSTALLATION

Dimensions

Panel Mounting

Make the recommended panel cutout.  Place the included gasket
over the rear of the unit and place the unit in the panel cutout.
Slide the panel mount bracket into place over the unit's rear
allowing the bracket tabs to engage the grooves on the case.
Continue to push forward until the bracket arm fits snugly
against the panel.

VEEDER-ROOT

123456

48 mm

24

mm

60

mm

8

mm

Bracket Arm

Mounting

Grooves

REAR TERMINAL CONNECTIONS

Quadrature Input (Encoder):

For bi-directional counting
connect corresponding en-
coder outputs to  channel
A & B input terminals. The
eccoder shield wire should be
connected to earth ground at
the counter.

1    2    3    4    5    6    7    8

1    2    3    4    5    6    7    8

1    2    3    4    5    6    7    8

Contact

Channel A

Common

12 VDC

Signal Input (transistor):

  Sig-

nal pulses are accumulated for
count and tachometer versions.
For timer versions, timer runs
when signal is present.  See
"Programming" for selection of
PNP or NPN signal

Signal Input (from switch):

 Con-

tact closure signals are accumu-
lated for count and tachometer
versions.  For timer versions the
timer runs when contact is closed.
See "Programming to select low
speed, NPN mode.

Channel B

Wiring

Insert wire into the appropriate openings as pictured in the drawing
below.  Turn the screws, located on the rear of the terminal block to
tighten the clamp and secure the wire.

Solid State Output:

  When the

factory programmed preset
value is reached a PNP output
will be triggered.  The output
will stay active until a reset
signal is received.

1    2    3    4    5    6    7    8

1    2    3    4    5    6    7    8

Contact

1    2    3    4    5    6    7    8

 (Common)

+ (12 to 24 VDC)

Power Wiring:

 Connect to 12

- 24 VDC (+20%/-10%) volt-
age source.  Power require-
ment is 5 mA, Maximum

Remote Reset:

 the displayed

value will be reset. Signal  in-
put is ignored when the Reset
is active. 

For tachometer

 

ver-

sions

, this input is not used.

1    2    3    4    5    6    7    8

Gate Input:

  all incoming sig-

nals will be ingnored and the
present display value will be
held.

 For Position Indicator

versions

, this input is not used.

Note:  Counting reletive to the encoder shaft
rotation can be reversed by swaping Channel A
and Channel B connections

Recommended Panel Cutout: 22mm (

±

0.3mm) X  45mm (

±

0.6mm)

Load

+

+

10mA DC Maximum

+

+

Contact

NPN

PNP

PNP

NPN

PNP

NPN

Summary of Contents for C342 Series

Page 1: ...tory programmable features Setpoint Scale Value Decimal Position Text Message IEC IP65 rated front panel for use in washdown environments Index Overview Installation page 2 Terminal Connections page 2 Setup Front Panel Operation page 3 Programming page 3 General Specifications page 4 Ordering Information page 4 Warranty page 4 Models Covered in this Manual C342 0464 Totalizer Accumulates and displ...

Page 2: ...nals are accumu lated for count and tachometer versions For timer versions the timerrunswhencontactisclosed See Programming to select low speed NPN mode Channel B Wiring Insert wire into the appropriate openings as pictured in the drawing below Turn the screws located on the rear of the terminal block to tighten the clamp and secure the wire Solid State Output When the factory programmed preset va...

Page 3: ... down the the FRP key for seconds to select it Scroll between the two Front Panel Enable choices by brief press and release of the FPR key Hold the FPR key for 2 sconds to select the desired choice and return to Operating Mode Note The NPN PNP selection applies to the Signal Reset and Hold inputs PROGRAMMING During Power up C342 0562 Totalizer The instrument will accumulate and display the pulses ...

Page 4: ...y Programmable Settings Setpoint Prescale Value Decimal Position Text Message Specifcy the setting and value when placing an order Ex Setpoint 4567 Standard products manufactured by the Company are warranted to be free from defects in workmanship and material for a period of one year from the date of shipment and products which are defective in workmanship or material will be repaired or replaced ...

Reviews: