background image

3

  

 -  

 BATT     +

  

 

+     BATT    -

68mm

72mm

8

7

6

5

4

3

2

1

33mm

36mm

Battery Slots

Front Panel Installation - 

Place the unit in the panel through the

33mm x 68mm cutout.  Slide the included gasket over the rear of the
unit, then slide the panel mount bracket into place so that the 4 tabs
catch in the groves on the top and the bottom of the unit (the bracket
should be oriented so that the tabs are on the side nearest the panel).
Used the provided panel mount screws to tighten the bracket until
there is a secure seal against the gasket.

Battery Installation

 - The unit is shipped with one battery, which is not

installed.  Remove the battery cover by pushing inward and down.  Install
the battery in either of the two slots.  The unit runs on a single battery,
and the second slot is provided to allow for installing a new battery before
removing the old one, retaining count total and program data.  The unit
can also be run on two batteries to extend the  battery life to 10 years.
Once the battery is in place the unit will go into a self test mode, and all
the segments on the LCD display will be illuminated.  The self test mode
is exited by depressing the Next key, which will then display the model
number (1).  Depress the Next key again to ready the unit for operation.

INSTALLATION

S E T U P

PROGRAMMING

Programming parameters can be accessed, when the Program Enable input is active, by
pressing the Down key.  To edit a parameter use the Down key to scroll until the desired
parameter appears on the screen.  Pressing the Next key will cause the leftmost digit of
that value to begin to flash.   Use the Next and Down keys in combination to choose
individual digits and change their value.

1 . 0 1 . 0 0 0 0

Count Input Calibrator: 

 Multiplies the input pulses by a value settable from  0.0001 to 99.9999, and

displays the results as the count value.

o F F

Count Offset - 

Enables the counter to be reset to a value other than 0.  Settable in a range from

-999999 to 999999.

Display Decimal Point:  

Sets the decimal point on the count display from Off to 0.00000.  The Next key

is used to scroll through the choices.

2 .

4 .

3 . 000000

o n

Front Panel Reset Enable:

  When active (ON) the count value, when being displayed, can be reset by

pressing the Next/Reset key.  If set to OFF, the total value can only be reset through the remote input..

Reviews: