IQ Control Box Installation and Owner’s Manual
Specifications
2
Specifications
WARNING
FAILURE TO COMPLY WITH THE FOLLOWING WARNINGS AND SAFETY PRECAUTIONS
COULD CAUSE DAMAGE TO PROPERTY, ENVIRONMENT, RESULTING IN SERIOUS
INJURY OR DEATH.
1. All installation work must comply with the latest issue of the National Electrical Code
(NFPA 70), the Code for Motor Fuel Dispensing Facilities and Repair Garages (NFPA
30A), and any European, national, state, and local code requirements that apply.
2. To protect yourself and others from serious injury, death, or substantial property
damage, carefully read and follow all warnings and instructions in this manual.
Parameter
Value
Unit
Electrical
Input Voltage Range
200 to 250
V
Input Voltage Frequency
47.5 to 61.8
Hz
Maximum Motor Rating
2
HP
Dispenser Interface (-051, -058)
101 to 132
VAC
Dispenser Interface (-051, -058)
3
mA
Dispenser Interface (-052, -059)
192 to 264
V
Dispenser Interface (-052, -059)
5
mA
Voltage Reading Accuracy
0.1
%
Current Reading Accuracy
0.8
%
Communications
RS-485
Environmental
Ambient Temperature Range
0 to 40
°C
Storage Temperature Range
-20 to 65
°C
Mechanical
External Dimensions (-051, -052)
6.75 x 7.63 x 4.00
Inches (Height x Width x Depth)
External Dimensions (-058, -059)
6.75 x 7.63 x 6.05
Inches (Height x Width x Depth)
Terminal Block Screw Size
8-32
NOTES:
1. All specifications at an ambient temperature of 25 °C.
2. Wiring must be rated 90°C minimum.