CONNECTING IF BATTERY IS OUTSIDE OF VEHICLE

CONNECTING IF BATTERY IS OUTSIDE OF VEHICLE

a

) Check polarity of battery posts- For top-mounted battery connectors, the positive post (marked 

POS,

P, +) 

usually has a larger diameter than the Negative battery post (marked NEG, N, 

--

).

  

For side-

mounted battery connections the Positive terminal is red, the Negative terminal is black.

b) Attach a 24-inch (minimum length) 6 AWG insulated battery cable to the Negative battery post

(marked NEG, N, -)

c) Connect the Positive (RED) battery clamp to the Positive battery connector (marked POS, P, 

or red).

d) Stand as far back from battery as possible, and do not face battery when making final connection.

e) Carefully connect the Negative (BLACK) charger clamp to the free end of the battery cable connected

to the negative terminal. Connect the charger

*

s power cord to a grounded 110/120 volt AC power

outlet, and refer to Appendix A for approximate charging times.

f) Set charger

*

s charge rate to appropriate setting according to battery size.

g) When charging is complete, disconnect cables and clamps in reverse order from which they were

connected.

CHARGING TIMES

CHARGING TIMES

The VEC088 is a fully automatic battery charger. It automatically adjusts the charge rate as the battery

becomes charged and stops charging when the battery is fully charged. if you require some estimate of

the time 

it 

takes to charge a battery refer to Appendix A for these details.

BATTERY RECONDITION MODE

BATTERY RECONDITION MODE

NOTE

NOTE::  BATTERY RECONDITION mode does not charge any battery. Charging is a separate operation.

The battery to be treated does not have to be installed in a vehicle. Follow the instructions for Connecting

if Battery is Outside of Vehicle.

BATTERY RECONDITION MODE should only be used with 10 Amp Hour or larger capacity lead-acid

batteries. Charge the battery to be treated for 20 minutes, before using RECONDITION Mode. Observe

the Digital Display for any codes. This initial charge will check the battery for shorted cells (F01), open

cells or battery too low (or overcharged) to accept a charge (F02), and to ensure the battery can take a

charge. if code F03 is displayed, change modes to the BATTERY RECONDITION MODE.

Whenever a lead acid battery begins to discharge, lead sulfate, an insulator, begins to build up on the

plates in the battery. This reduces the ability of the battery to hold a full charge. When that battery has an

immediate charge, most of the lead sulfate is dissolved and the plates are free of 

is insulation. If a

battery remains in a discharged condition, the lead sulfate changes to a hard crystalline form, making a

full charge difficult. BATTERY RECONDITION mode sends a sequence of electronic pulses into the

battery, shaking loose and dissolving the crystals. This slowly (over 24 hours) removes the insulating

buildup from the plates so the battery can hold a full charge. Most automotive batteries (50 to 70AH) can

be treated once to reduce the lead sulfate buildup. Smaller 12 volt batteries, such as found in jump

starters can be treated for 12 hours. However depending on the severity of lead sulfate buildup and a

larger size of the battery, up to five 24 hour treatments may be necessary. Battery Restore mode

automatically operates and then times out after 24 hours. When a smaller battery is treated, Battery

Restore mode can be manually stopped after 12 hours of treatment.

To start the BATTERY RECONDITION MODE, press Battery Recondition, the first 

seconds the display

will show dES then change to moving bars for the reminder of the timing period. After 24 hours the timer

will stop the operation. The digital display will show the circulating pattern. If the battery is not fully

charged, charge the battery until FUL is displayed on the digital display.

NOTE:

NOTE:  Battery Recondition Mode can treat a severely sulfated battery up to five times. If performance of

the battery does not improve, recycle the battery.

VEC088

8

Summary of Contents for VEC088

Page 1: ......

Page 2: ...ng conductor and a grounding lug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances See Figure 1 DANGER DANGER NEVER NEVER alter AC cord or plug provided if it will not fit outlet have proper outlet installed by a qualified electrician Improper connection can result in the risk of an electric shock This battery charger ...

Page 3: ... battery posts and twist or rock back and forth several times to make a good connection This tends to keep clips from slipping off terminals and helps to reduce risk of sparking FOLLOW FOLLOW THESE THESE STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUS STEPS WHEN BATTERY IS INSTALLED IN VEHICLE A SPARK NEAR BATTERY MAY CAUSE E BATTERY EXPLOSION TO REDUCE RISK OF A SPARK NEA...

Page 4: ... Stage Three continues and turns OFF when the battery reaches full charge This charger has a CHARGING COMPLETE LED and the digital display shows FUL when the battery is fully charged FIGURE FIGURE 2 CHARGE CURVE CHARGE CURVE FEATURES FEATURES The unit has three charge rate setting with a 2 6 12A pushbutton charge rate switch a 2 amps smaller batteries as in lawn mowers snowmobiles motorcycles etc ...

Page 5: ......

Page 6: ......

Page 7: ...e vehicle chassis or the engine block away from the battery Do not connect the clamp to the carburetor fuel lines or sheet metal body parts connect only to a heavy gauge metal p art of the frame or engine block NOTE NOTE NEGATIVE GROUNDED type systems are the most common in today s vehicles c Set charger s charge rate to appropriate setting 2 6 12A according to battery size POSITIVE GROUNDED POSIT...

Page 8: ...utes before using RECONDITION Mode Observe the Digital Display for any codes This initial charge will check the battery for shorted cells F01 open cells or battery too low or overcharged to accept a charge F02 and to ensure the battery can take a charge if code F03 is displayed change modes to the BATTERY RECONDITION MODE Whenever a lead acid battery begins to discharge lead sulfate an insulator b...

Page 9: ...likely that the alternator is good NOTE NOTE Do not turn on air conditioning or the defroster system to load the alternator These appliances may start operating in the middle of a measurement cycle and give an invalid results if the first check indicates the alternator is good and the second or third repeat of the check indicates the alternator is bad there probably is some problem in the system P...

Page 10: ...ept a high rate of charge since the internal plates are coated with lead sulfate To see if a battery in this condition can be saved follow the instructions in battery recondition INTERNAL SHORT CELL BATTERY INTERNAL SHORT CELL BATTERY F01 If the battery being charged has internal short cell the FAULT LED will light Using a voltmeter determine the voltage of the battery and if it is under 12 volts ...

Page 11: ...imate charging times PERCENT OF CHARGE PERCENT OF CHARGE 75 75 50 50 25 25 0 0 2 AMPS 7 HRS 13 HRS N R N R 6 AMPS 2 5 HRS 5 HRS 7 HRS 9 HRS 12 AMPS 1 2 HRS 2 5 HRS 3 2 HRS 4 6 HRS Not Recommended because over 18 hrs charging time The times shown in the chart above are approximate and refer to an average automotive battery For smaller batteries the charge time should be adjusted using the formula s...

Page 12: ...lting from normal wear and and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents damage during shipping to our service facility alterations unauthorized use or repair neglect misuse abuse failure to follow instructions for care and maintenance fire flood and Acts of God if your problem is not covered by this warranty call our Technical ...

Reviews: