background image

4

CAUTION:

Caution statements advise against certain conditions and practices

that may result in damage to vehicles, appliances and/or the Jump-

Starter.

IMPORTANT:

Although this unit is delivered in a partially charged state, you must fully charge it

with the supplied 110/120 Volt AC charger for a full 24 hours before using it for

the first time. You cannot overcharge the unit using the AC charger method.
1. Use only the supplied cords/adapters for recharging this unit. Do not recharge

for more than 3-4 hours maximum using 12 Volt DC method. Recharge unit

after each use.

2. All On/Off switches should be in the OFF position when the unit is charging

or not in use. Make sure all switches are in the OFF position before connection

to a power source or load.

3. Never insert anything other than the supplied power/recharging cords or 

recommended appliance power/recharging cords into the 12 Volt DC

charging/power outlet on this unit. Do not use any accessory that is not

recommended or provided by the manufacturer.

4. Do not use this unit to operate appliances that draw more than 5 amps.
5. This system is designed to be used only on vehicles with 12 Volt DC battery 

systems. Do not connect to a 6 Volt or 24 Volt battery system.

6. This system is not designed to be used as a replacement for a vehicular battery.

Do not attempt to operate a vehicle that does not have a battery installed.

7. Vehicles that have on-board computerized systems may be damaged if vehicle

battery is jump-started.  Before jump-starting, read the vehicle’s owners

manual to confirm that external-starting assistance is advised. 

8. Excessive engine cranking can damage a vehicle’s starter motor. If the engine

fails to start after the recommended number of attempts, discontinue jump-start

procedures and look for other problems that may need to be corrected.

9. Although this unit contains a non-spillable battery, it is recommended that unit

be kept upright during storage, use and recharging. To avoid possible damage

that may shorten the unit’s working life, protect it from direct sunlight, direct

heat and/or moisture.

10. Check unit periodically for wear and tear. Replace worn or defective parts

immediately. Contact Vector Customer Service department toll-free

866-584-5504.

11. Do not attempt to jump-start a frozen battery.
12. Never submerge this unit in water.
13. DO NOT over-inflate tires.

Summary of Contents for START-IT VEC022DSCC

Page 1: ...MATION YOU SHOULD KNOW Jump start any engine system with a standard 12 Volt DC battery Easy to read series of LED charge indicators Jump Start System can be recharged from any standard 110 120 Volt AC...

Page 2: ...Fuse 11 4 4 Estimated Battery Life 11 5 OPERATING AS A PORTABLE POWER SUPPLY 11 6 EMERGENCY AREA LIGHT 12 7 COMPRESSOR TIRE INFLATOR 12 7 1 Warnings for Compressor Use 13 7 2 Tire Inflation or Product...

Page 3: ...sion 9 When using this unit in proximity to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehic...

Page 4: ...5 amps 5 This system is designed to be used only on vehicles with 12 Volt DC battery systems Do not connect to a 6 Volt or 24 Volt battery system 6 This system is not designed to be used as a replace...

Page 5: ...ART SYSTEM to Jump start any engine system with a standard 12 Volt DC battery boat truck car airplane RV personal watercraft snowmobile garden tractor gasoline engine generator etc Operate 12 Volt DC...

Page 6: ...ose Tire Chuck 6 Positive Red Clamp 7 INFLATOR Push Button 8 FAULT LED Indicator 9 ALARM LED Indicator 10 Display 11 Display ON OFF Push Button 12 LED Indicator 13 System Check Push Button 14 Alternat...

Page 7: ...button will light the LCD display Pressing ON OFF will turn the unit s display on and off LIGHT turns the area light ON and OFF CHARGE LEVEL displays the internal battery percentage of the jumpstarte...

Page 8: ...water 9 Do not wear vinyl clothing when jump starting a vehicle friction can cause dangerous static electricity sparks Remove all jewelry or metal objects they can cause short circuits or react with...

Page 9: ...ct negative black clamp to chassis or a solid non moving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part 5 Procedure for jump starting POSITIVE GR...

Page 10: ...ion occurs seek immediate medical attention EYES If battery acid comes in contact with eyes flush eyes immediately for a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION 4 CHARGING RECHARGIN...

Page 11: ...ring DC charging disconnect DC adapter from accessory outlet push unit s ON OFF button to activate the display then push Charge Level button 4 DO NOT EXCEED 3 4 HOURS MAXIMUM 5 When charging is comple...

Page 12: ...e area light s operating life is 100 000 hours 7 AIR COMPRESSOR TIRE INFLATOR IMPORTANT Read Instructions Carefully To Avoid Possible Injury or Property Damage The built in 12 Volt DC air compressor i...

Page 13: ...res use of one of the adapters nozzles 1 Open the hatch and remove the nozzles noting their storage positions 2 Insert appropriate adapter e g needle into connector chuck and close thumb latch 3 Refer...

Page 14: ...tery protect exposed terminals with heavy duty electrical tape to prevent shorting shorting can result in injury or fire Do not expose battery to fire or intense heat as it may explode 8 2 BATTERY DIS...

Reviews: