background image

10

CAUTION:

• If engine fails to start, leave ignition key turned off and disconnect the

negative (-) clamp first, then the positive (+) clamp. Try again later – the

engine may be flooded.

• Recharge jump-start system after each use.

WARNING:

• Always disconnect the engine or frame jumper clamp first; followed by the

battery jumper clamp 

• Never allow red and black clamps to touch each other or another common

metal conductor; this could cause damage to the unit and/or create

sparking/explosion hazard

• There is a risk of explosive gases being released when batteries are charged

or discharged, failure to follow instructions may cause property damage,

explosive hazard, and/or personal injury

• Always use protective eyewear when using this product: contact with battery

acid may cause blindness and/or severe burns

• Keep out of children’s reach
• ALWAYS store battery clamps on built-in clamp holders when not in use and

never touch battery clamps together, this can cause dangerous sparks, power

arcing and/or explosion

FIRST AID:

• SKIN: If battery acid comes in contact with skin, rinse immediately with

water, then wash thoroughly with soap and water. If redness, pain, or

irritation occurs, seek immediate medical attention

• EYES: If battery acid comes in contact with eyes, flush eyes immediately for 

a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION

4.

CHARGING/RECHARGING

For maximum battery life, we recommend the VECTOR®Jump-Start system be

kept fully charged at all times. If the battery is allowed to remain in a

discharged state, battery life will be shortened. 

NOTE

: Recharging battery after each use will prolong battery life; frequent

discharges between recharges will reduce battery life.

IMPORTANT

: MAKE SURE ALL FUNCTIONS ARE TURNED OFF DURING

RECHARGING

• Charge unit for full 24 hours using AC method, prior to first use
• Recharge unit fully after each use
• Recharge unit every month, when not in use for optimum performance

4.1 110/120 VOLT AC CHARGING

1. Simply plug the AC plug of the AC/DC adapter/charger into any

standard 110/120 volt AC wall outlet.

2. Plug the barrel connector attached to the AC/DC adapter into the small

barrel receptacle on the jump-starter that is marked recharge port.

NOTE

: Unit’s ON/OFF button must be pressed first for LCD display to be

activated.

3. After initial 24 hour charge, charge this device for at least 14-16 hours

after each use or until FULL is displayed when Charge Level button is

pressed.

4. When charging is completed, remove the AC/DC charger plug and store

in a safe place.

Summary of Contents for START-IT VEC022DSCC

Page 1: ...MATION YOU SHOULD KNOW Jump start any engine system with a standard 12 Volt DC battery Easy to read series of LED charge indicators Jump Start System can be recharged from any standard 110 120 Volt AC...

Page 2: ...Fuse 11 4 4 Estimated Battery Life 11 5 OPERATING AS A PORTABLE POWER SUPPLY 11 6 EMERGENCY AREA LIGHT 12 7 COMPRESSOR TIRE INFLATOR 12 7 1 Warnings for Compressor Use 13 7 2 Tire Inflation or Product...

Page 3: ...sion 9 When using this unit in proximity to the vehicle s battery and engine stand the unit on a flat stable surface and be sure to keep all clamps cords clothing and body parts away from moving vehic...

Page 4: ...5 amps 5 This system is designed to be used only on vehicles with 12 Volt DC battery systems Do not connect to a 6 Volt or 24 Volt battery system 6 This system is not designed to be used as a replace...

Page 5: ...ART SYSTEM to Jump start any engine system with a standard 12 Volt DC battery boat truck car airplane RV personal watercraft snowmobile garden tractor gasoline engine generator etc Operate 12 Volt DC...

Page 6: ...ose Tire Chuck 6 Positive Red Clamp 7 INFLATOR Push Button 8 FAULT LED Indicator 9 ALARM LED Indicator 10 Display 11 Display ON OFF Push Button 12 LED Indicator 13 System Check Push Button 14 Alternat...

Page 7: ...button will light the LCD display Pressing ON OFF will turn the unit s display on and off LIGHT turns the area light ON and OFF CHARGE LEVEL displays the internal battery percentage of the jumpstarte...

Page 8: ...water 9 Do not wear vinyl clothing when jump starting a vehicle friction can cause dangerous static electricity sparks Remove all jewelry or metal objects they can cause short circuits or react with...

Page 9: ...ct negative black clamp to chassis or a solid non moving metal vehicle component or body part Never clamp directly to negative battery terminal or moving part 5 Procedure for jump starting POSITIVE GR...

Page 10: ...ion occurs seek immediate medical attention EYES If battery acid comes in contact with eyes flush eyes immediately for a minimum of 15 minutes and SEEK IMMEDIATE MEDICAL ATTENTION 4 CHARGING RECHARGIN...

Page 11: ...ring DC charging disconnect DC adapter from accessory outlet push unit s ON OFF button to activate the display then push Charge Level button 4 DO NOT EXCEED 3 4 HOURS MAXIMUM 5 When charging is comple...

Page 12: ...e area light s operating life is 100 000 hours 7 AIR COMPRESSOR TIRE INFLATOR IMPORTANT Read Instructions Carefully To Avoid Possible Injury or Property Damage The built in 12 Volt DC air compressor i...

Page 13: ...res use of one of the adapters nozzles 1 Open the hatch and remove the nozzles noting their storage positions 2 Insert appropriate adapter e g needle into connector chuck and close thumb latch 3 Refer...

Page 14: ...tery protect exposed terminals with heavy duty electrical tape to prevent shorting shorting can result in injury or fire Do not expose battery to fire or intense heat as it may explode 8 2 BATTERY DIS...