background image

5

FIGURE 2

1.2   KEY FEATURES

•  On/off safety power switch (no key required, no key to get lost!)

•  Cordless/rechargeable-includes recharge adapters for standard 120 volt AC wall socket 

  and vehicle’s 12 volt DC accessory outlet using adapter cables

•  Powerful 400 boost amps; 1200 peak amps

•  Includes non-spillable, maintenance-free, heavy duty, 19 ampere hour, sealed, lead-acid battery 

•  Audible polarity alarm to warn of reverse polarity

•  Requires no maintenance (other than recharging) for optimum operation

•  Heavy  duty,  industrial  grade  copper  clamps  and  #4  AWG  jumper  cables-with  exclusive  

  recessed cable holsters

•  Built-in 120 PSI compressor with lighted gauge

•  Built-in, removable fluorescent lantern

•  Storage channels that keep jumper cables and the compressor hose out of the way until they  

  are needed and allow Power City to securely lay against flat surfaces

•  110 volt AC charger is Underwriter Laboratories safety tested and listed

•  Easy-to-read LED battery charge status display - activated by pressing the charge status  

  button and automatically activated during AC recharge

1.3      USE POWER CITY TO:

•  Jump-start (using heavy duty battery cable and clamps) any vehicle with a standard 12 volt    

DC battery system: boat, truck, car, airplane, RV,  personal watercraft, snowmobile, tractor, etc.

•  Power/recharge: AC laptop computers and printers, color TVs up to 13”, reading lamps, 

  fans,  small  appliances  and  power  hand  tools,  cellular  phones,  camcorders,  power  tool  

  rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC  

  standard-type plug

•  Operate (using 23 ampere rated 12 volt accessory sockets): 12 volt DC fans, fluorescent  

  worklights, air compressors, spotlights, TVs, portable radios, cassette or CD players and  

  more. Can operate and quick-charge a cellular phone by using the phone’s 12 volt DC   

  adapter cord

•  Inflate  truck,  auto,  motorcycle  and  trailer  tires  and  small  popular  beach  and  camping  

  accessories such as volley balls, soccer beach balls, saving valuable time and effort 

•  Illuminate areas: under the hood, inside tents, work areas while changing tires, etc. Lantern  

  is removed from main unit and powered by an extension cord, for light where you need it

NOTE:

 Other appliances may also be used with the Power City as long as they do not exceed  

    the 23 ampere limit of the units 12 volt DC accessory outlet, or the 200 watt limit of the  

    inverter.
READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY, BEFORE USING THIS 

PRODUCT. FOLLOW RECOMMENDED WARNINGS, CAUTIONS, AND SAFETY PROCEDURES 

AND MANUFACTURER’S GUIDELINES FOR YOUR VEHICLE BATTERY.

IMPORTANT:

 This unit is delivered in a partially charged state - you must fully charge it   

  before using it for the first time. Initial AC Charge should be for 24 hours.
Refer to Section 7 for use of recharge cables, AC adapter and detailed charging instructions.

1.   NEGATIVE (BLACK) 

 

CLAMP

2.   AIR COMPRESSOR  

 

ON/OFF SWITCH

3.   AC RECHARGE PORT

4.   POSITIVE (RED) CLAMP

5.   AIR COMPRESSOR  

 

PRESSURE GAUGE

6.   120 VOLT AC CHARGER

3

6

5

4

1

2

Summary of Contents for Power City DK080706

Page 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Page 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Page 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Page 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Page 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Page 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Page 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Page 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Page 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Page 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Page 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Page 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Page 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Page 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Page 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Page 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Page 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Page 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Page 19: ...19...

Page 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...