16
5. Charge the unit until the green CHARGED indicator is lit when the charge status button is
pressed - DO NOT EXCEED 8 HOURS MAXIMUM.
6. After charging, disconnect the cables and store them in the cable storage hatch.
7.3 ALTERNATE DC RECHARGE
If the Inverter is removed from the main unit, the DC recharge cable can be directly connected to
the black power connector that mates with the inverter’s flat power pins. In this way, the inverter
and inverter power cable can be used away from the main unit and DC recharge can be ac-
complished. Follow the same charging time and monitor the battery charging by using the battery
status pushbutton and display.
7.4 SIMULTANEOUS DC RECHARGE AND INVERTER OPERATION
Connecting the inverter power cable and the DC recharge cable makes a heavy-duty DC-to-DC
cable that can simultaneously recharge the main unit and operate the Inverter while it is mounted
on Power City. Plug one DC plug into Power City accessory outlet and the other DC plug into a
vehicle accessory outlet. When using with AC appliances that draws over120 watts, and at the
same time the Power City’s battery is deeply discharged, this could draw more than the vehicle’s
accessory outlet fuse can handle and result in a blown fuse. Use this method with caution. Periodi-
cally monitor DC recharge using the battery status pushbutton and indicators.
8.
MAINTENANCE/REPLACEMENT PARTS
For replacement parts (bulbs, batteries, charging adapters, cables, etc.), contact Vector
Technical Support toll-free 866-584-5504. Except for a fuse in the inverter and a lamp in the
lantern, there are no user serviceable parts inside Power City. Periodically, the cables and con-
nectors should be inspected for damage, corrosion, dust, and dirt. If surfaces are dirty, they can
be wiped clean with a cloth moistened with water and a small drop of detergent. Contacts can
be wiped clean with a dry cloth.
WARNINGS:
Other than a fuse in the inverter and a lamp in the lantern, there are no user
serviceable parts inside. DO NOT operate unit if there is any evidence of damage. The
product must be returned to Vector for testing and repair. Replace any damaged cables
immediately before further use.
Refer to section 4.6 for inverter fuse replacement. Refer to section 6.4 for lamp replacement.
9.
BATTERY DISPOSAL
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of
properly. Recycling is required. Contact your local authority for information. Failure to comply
with local, state and federal regulations can result in fines, or imprisonment. Sealed lead battery,
must be recycled or disposed of properly. For more information on recycling this battery, call
toll-free 877-288-7722.
BATTERY DISPOSAL WARNINGS:
• Do not dispose of the battery in fire as this may result in an explosion
• Before disposing of the battery, protect exposed terminals with heavy-duty electrical tape to
prevent shorting (shorting can result in injury or fire)
• Do not expose battery to fire or intense heat as it may explode