6.3   LAMP REPLACEMENT

The only lamp is in the lantern assembly. For any maintenance of the lamp, you will need a small 

Phillips screwdriver and a soft clean cloth. Replacement bulbs are available from Vector Techni-

cal Support Department call toll-free 866-584-5504 for replacements. 

WARNING:

 Fluorescent 

bulbs are fragile, be careful while handling. 

NOTE

: DO NOT use any metal tools to remove or replace bulb. (See Figure 11)

FIGURE 11

1.     Make sure the lantern is turned off.

2.    Remove the lantern assembly from the main unit.

3.     Remove the Phillips type screw (turn counter-clockwise).

4.    Lift the lens upward and off and set it aside.

5.    Using a clean cloth, rotate the top of the bulb away from the reflector. 

6.    Pull  the  burned  out  bulb  upwards  and  towards  the  front  of  the  lantern  assembly,  

      and remove.

7.    Replace with a new fluorescent 11 watt bulb.

8.    Snap the lens into place (bottom tab first) and replace the two screws.

9.    Carefully turn the screw clockwise to tighten. DO NOT OVER TIGHTEN screw.

10.  Dispose of burned out bulb in a responsible manner. Follow local ordinances for disposal.

7.  

RECHARGING POWER CITY’S BATTERY

Lead-acid batteries require maintenance to maintain a full charge and to ensure good battery 

life. All lead-acid batteries suffer from self-discharge over time and more rapidly when they are 

at higher temperatures. Therefore, these types of batteries need periodic charging to replace 

energy lost through self-discharge. When Power City is not in use, Vector recommends that the 

batteries be recharged at least every 60 days.
All batteries must be recharged as soon as possible after each use. If a battery is allowed to 

remain in a discharged state, battery life will be reduced.

NOTE:

 Recharging battery after each use will prolong battery life; frequent heavy discharges  

    between recharges will reduce battery life. Overcharging will reduce battery life.
The  battery  can  be  recharged  using  several  different  methods.  The  time  required  to  fully  

recharge  these  batteries  depends  on  the  charge  status  of  the  battery  after  the  use  of  DC  

appliances, inverter and compressor. 

NOTE:

  Pressing  the  battery  status  pushbutton  turns  on  the  battery  status  display  on  the  

    main unit 
Check the battery charge level by pressing the charge status button. The LED charge status display 

will indicate the level of charge of the battery.

Summary of Contents for Power City DK080706

Page 1: ...S INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE 4140 S W 30TH AVE FT LAUDERDALE FL 33312 TEL 9...

Page 2: ...erized systems may be damaged if vehicle battery is jumpstarted Before jump starting this type of vehicle read the vehicle s owner s manual to con rm that external starting assistance is advised Exces...

Page 3: ...4 7 Inverter fuse replacement 11 5 COMPRESSOR TIRE INFLATOR 11 5 1 Compressor use 11 5 2 Warnings 11 5 3 Tire In ation or products with a valve stem 12 5 4 In ate other articles without valve stem 12...

Page 4: ...luable when it becomes necessary to locate battery terminals while preparing to jumpstart a dead battery in the dark changing a tire etc Power City is also ideal to power 12 volt DC cordless portable...

Page 5: ...er hand tools cellular phones camcorders power tool rechargeable batteries that have an appropriate recharging adapter with a 120 volt AC standard type plug Operate using 23 ampere rated 12 volt acces...

Page 6: ...nected to chassis most common 4 Make sure Power City s main unit safety switch is turned off 5 Carefully lift negative black jumper cable wire from storage channel starting at clamp end of cable 6 Squ...

Page 7: ...the inverter and it is operating properly The red LED when lit indicates that something caused the inverter to shut down The green LED will not be lit under shutdown conditions Inverter shutdown is c...

Page 8: ...s operated away from the main unit the power source must provide between 11 and 14 5 volts DC and must be able to supply the necessary current amps to operate the load The power source may be a batter...

Page 9: ...age to the inverter THIS WILL VOID THE WARRANTY If the inverter is connected to the incorrect polarity the fuse will blow If the unit does not function after replacement of the fuse the unit must be r...

Page 10: ...ece of equipment that is generating heat above room temperature Keep the inverter away that from direct sunlight if at all possible VENTILATED Keep the area surrounding the inverter clear to ensure fr...

Page 11: ...volt DC accessory socket 5 COMPRESSOR TIRE INFLATOR This built in 12 volt DC compressor is the ultimate compressor for all vehicles trailer tires and recreational in atables Three different sized nozz...

Page 12: ...very rapidly 5 Insert adaptor e g needle into item to be in ated and in ate to desired pressure 6 Turn on compressor switch in ate to desired pressure or fullness refer to paragraph 5 5 7 Remove adapt...

Page 13: ...on and during under the hood inspections See Figure 9 If an alternative 12 volt DC source is avail able the lantern can be powered from a standard 12 volt accessory socket The lantern draws 11 watts s...

Page 14: ...sponsible manner Follow local ordinances for disposal 7 RECHARGING POWER CITY S BATTERY Lead acid batteries require maintenance to maintain a full charge and to ensure good battery life All lead acid...

Page 15: ...in their own cable storage hatch in the main unit Recharging the main unit s internal battery from an external DC power source requires the use of the DC recharge cable and the inverter power cable Se...

Page 16: ...cement parts bulbs batteries charging adapters cables etc contact Vector Technical Support toll free 866 584 5504 Except for a fuse in the inverter and a lamp in the lantern there are no user servicea...

Page 17: ...Power Inverter Continuous 200 Watt 60 Hz 110 120 VAC Power Inverter Peak 350 Watt 60 Hz 110 120 VAC Inverter Waveform Modi ed Sine Wave Inverter DC Input Range 10 0 to 14 6 VDC Inverter Audible Alarm...

Page 18: ...not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight accidents d...

Page 19: ...19...

Page 20: ...20 2006 VECTOR PRODUCTS INC FT LAUDERDALE FL 33312 MADE IN CHINA DK080706...

Reviews: