Battery Operating Time

1. Always turn power switch on the inverter to OFF position when unit is not in use. If

the switch is left in the ON position, it will drain the 

Pocket Generator™

battery.

2. 

WARNING: Never run both AC and DC devices at the same time as this can

damage the Pocket Generator™.

3. Always recharge unit after using.

With a full charge, the 

Power Force 50™

inverter will deliver a minimum

operating time of 30 minutes to one hour. In most instances, 1-3 hours of
operating time is achievable (see chart below).

TROUBLESHOOTING

Protective Features of the 

Power Force 50™

The 

Power Force 50™

monitors the following potentially hazardous conditions:

Low Battery Voltage -

this condition is not harmful to the inverter but could damage

the power source, so the inverter automatically shuts down when input voltage
drops to 10.0 volts. When this condition is corrected, the unit may be restarted.

Over Voltage Protection -

the 

Power Force 50™

will automatically shut down

when the input voltage exceeds 15 volts DC.

Short Circuit Protection -

Reverse polarity or a short circuit condition will usually

result in failure of the inverter’s fuse. Immediately disconnect the shorted load and
replace the fuse inside the 

Pocket Generator™

.

Estimated Operation Times:

110-VOLT AC APPLIANCE

APPROX. RUNNING TIME

50 WATT LAMP

40 MINUTES

LAPTOP / PRINTER

1.5 HOURS

DESK FAN

2.0 HOURS

STEREO/CD PLAYER

2.5 HOURS

CELLULAR PHONE, POWER TOOLS

5 TO 10 HOURS

& CAMCORDER CHARGERS

6. 

WARNING:

Do not run both AC and DC devices at the same time.

7. 

ALWAYS

turn OFF the 

Power Force 50™

inverter BEFORE charging the

Pocket Generator™

.

8. The nylon case that is provided with the 

Pocket Generator™

is water-resistant

only to the extent that it will help protect the unit from rain or water spray; never
immerse the unit in water (fresh or salt).

9. Do not expose the 

Pocket Generator™

to extreme heat or flames.

10. Do not exceed recommended charging times.
11. Continuous run times are limited, see charts for estimated operation times.

RECHARGING THE 

Pocket Generator™

CAUTION:

• 

IMPORTANT:

Before recharging from an AC power source, verify that the source

is 110 volts only. Do not plug this unit’s 110 volt charger into a 220 volt
power source.

• 

IMPORTANT:

Be sure that power inverter ON/OFF switch is in OFF position

before recharging.

Recharging From A 110-volt AC Power Source

1. Before initial use, it will take 18-20 hours to fully charge the 

Pocket Generator™

.

Subsequent charges will only take 12-15 hours (approx.). 

2. Insert the cigarette lighter plug at the end of the AC charger cord into the

matching 12 volt receptacle on the side of the 

Pocket Generator™

.

3. Plug the charger into any standard 110/120 volt AC electrical outlet. Never

plug a 110 volt charger into a 220 volt power source.

Recharging From A 12 volt DC Power Source

CAUTION:

Do not connect the 

Pocket Generator™

DC charger to a car or boat electrical

system (12 volt DC negative-ground only) without first starting the engine. Failure to
do so could damage the vehicle’s battery.

1. Insert the cigarette lighter plug at one end of the DC charger cord into the

matching 12 volt receptacle on the side of the 

Pocket Generator™

.

2. Insert the cigarette lighter plug at the other end of the cord into the vehicle’s

cigarette lighter receptacle. Rotate the plug slightly to ensure good contact. A
green L.E.D. light on the cigarette plug will indicate a proper connection.

3. The 

Pocket Generator™

should be charged initially for 4-6 hours, while driving,

before use. Subsequent charges should only require 2-4hours (approx.).

4. The DC charging system will not provide as full a charge as is obtained with a

110 volt charging system.

3

Summary of Contents for Pocket Generator VEC018

Page 1: ...ERATOR PORTABLE CORDLESS RECHARGEABLE POWER SUPPLY 110 VOLT AC 12 VOLT DC PATENT PENDING THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT P...

Page 2: ...t other than accessories that is returned to Vector Manufacturing within 30 days of the date of purchase will be replaced free of charge If such a product is returned more than 30 days but less than o...

Page 3: ...OW VOLTAGE SHUTDOWN ACTIVATION 10 0 VOLTS WAVE FORM MAX SINE WAVE OF AC RECEPTACLES ONE FUSE 10 AMP 2 Pocket Generator Portable Cordless Rechargeable Power Supply SYSTEM FEATURES Take your home or off...

Page 4: ...protect the unit from rain or water spray never immerse the unit in water fresh or salt 9 Do not expose the Pocket Generator to extreme heat or flames 10 Do not exceed recommended charging times 11 Co...

Page 5: ...loads such as electric stoves and heaters which require far more wattage than the Power Force 50 can deliver on a continuous basis Inductive loads such as TVs and stereos require more current to opera...

Page 6: ...erator When first using a rechargeable device monitor its temperature for the initial ten minutes of use to determine whether it emits excessive heat If excessive heat is detected it is a good indicat...

Page 7: ...nt 9 Figure 2 Power Force 50 Modified Sine Wave 1 2 3 4 6 To Use The Pocket Generator To Boost Vehicle s Low Battery System WARNING Be sure that the ON OFF switch on the inverter is in the OFF positio...

Page 8: ...ower whenever and wherever it is needed Simply fully charge before use and turn ON the power switch to operate small electronic devices such as laptop computers portable radio cassette CD players colo...

Reviews: