IMPORTANT SAFETY INSTRUCTIONS 

To ensure reliable service, your power inverter must be installed and used

properly. Please read the installation and operating instructions thoroughly

prior to installation and use. Pay particular attention to the WARNING and

CAUTION statements in this manual. The CAUTION statements advise

against certain conditions and practices that may result in damage to your

inverter. The WARNING statements identify conditions or practices that

may result in personal injury.

Read All Instructions Before Using This Power Inverter!

WARNINGS:

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:
1.  Do not connect to AC distribution wiring.
2. Remove appliance plug from outlet strip or turn off inverter before 

working on the appliance. Multiple outlet power strips with switches and

circuit breakers only interrupt power to the "hot" receptacle terminals. The 

"neutral" terminals remain powered with respect to the "ground" 

terminals.

3. Do not make any electrical connections or disconnections in areas 

designated as IGNITION PROTECTED. This includes 12 volt DC plug 

connections, and ring terminal connections.

4. This is not a toy - keep away from children.

CAUTIONS:

1. Do not use with positive ground electrical systems (the majority 

of modern automobiles, RVs, trucks and boats are negative ground). 

Reverse polarity connection will result in a blown fuse and may cause 

permanent damage to the inverter and will void warranty.

2. This inverter will not operate high wattage appliances or equipment that 

produce heat, such as hair dryers, microwave ovens and toasters.
3. Grounding the neutral will cause the inverter to shut down. Do not operate 

this inverter if it is wet. Do not install in engine compartment - install in a well 

ventilated area.

4. This inverter is not tested for use with medical devices.

IMPORTANT CABLE INFORMATION

Substantial power loss and reduced battery operating time results from 

inverters installed with cables that are not able to supply full power. Symptoms of

low battery power can result from cables that are either excessively long or an

insufficient gauge. The installer/operator should be especially aware of the

requirements to maintain secure, tight, water-resistant electrical connections and to

provide for strain relief for DC cables and appliance wiring. Cable insulation must

be the appropriate type for the environment.

Summary of Contents for Maxx SST VEC024

Page 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH...

Page 2: ...C plug connections and ring terminal connections 4 This is not a toy keep away from children CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks...

Page 3: ...ION 6 4 1 Power Source Requirements 6 7 4 2 Connection to Power Source 7 8 4 3 Connection to Load 8 9 4 4 Placement of Inverter 9 5 OPERATING TIPS 10 5 1 Rated Versus Actual Current Draw of Equipment...

Page 4: ...start up currents from large inductive loads could shut down the inverter Three major features are incorporated in SST First gradual voltage ramp upduring inverter start up This eliminates failed col...

Page 5: ...t converts the high voltage DC into 110 volts 60 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that have replaced the bulky transformers found in less techn...

Page 6: ...voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 20 to 30 volts low wh...

Page 7: ...volt DC plug firmly into the 12 volt DC socket of a vehicle or other DC power source CAUTION Connect directly to power source when operating above 175 watts NOTE Most automobile 12 volt DC circuits us...

Page 8: ...he positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5...

Page 9: ...o not use the inverter to recharge items that q can be plugged directly into an AC receptacle This problem does not occur with the majority of battery operated equipment Most of these devices use a se...

Page 10: ...nverter can be manually restarted by reseting the on off switch Resistive loads are the easiest for the MAXX 400 SST to run However larger resistive loads such as electric stoves or heaters usually re...

Page 11: ...SST monitors the following potentially hazardous conditions LOW BATTERY VOLTAGE This condition is not harmful to the inverter but could damage the power source An audible alarm will sound when input...

Page 12: ...emit a buzzing sound from their speakers when operated from the MAXX 400 SST power inverter This occurs because the power supply in the electronic device does not adequately filter the modified sine w...

Page 13: ...alarm Bad connection or wiring Tighten all DC sounds continuously connections Low battery Low battery voltage Recharge battery alarm sounds Remove load from inverter while recharging battery Motorize...

Page 14: ...You may also contact us by visiting our website www vectormfg com 10 SPECIFICATIONS Output Connection Dual North American Standard Receptacles Output Voltage Approx 110 volt AC RMS 60 Hz Output Curre...

Page 15: ...oes not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight acciden...

Page 16: ...2004 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA VECTOR MANUFACTURING LTD...