air circulation around the unit. Do not place items on or over the inverter

during operation. A fan is helpful if the inverter is operating at maximum

power outputs for extended periods of time. The unit will shut down if the

internal temperature exceeds operating temperatures. The unit will restart

after it cools.

SAFE - Do not use the inverter near flammable materials or

in any locations that may accumulate flammable fumes or

gases.

5. 

OPERATING TIPS

5.1  RATED VERSUS ACTUAL CURRENT DRAW OF EQUIPMENT

Most electrical tools, appliances and audio/video equipment have labels

that indicate the power consumption in amps or watts. Be sure that the

power consumption of the item you wish to operate is rated at 400 watts

or less (If the power consumption is rated in amps AC, simply multiply by

the AC volts (110) to determine the wattage). The inverter has overload

protection, so it is safe to try to operate equipment rated at 400 watts or

less. The inverter will shut down if it is overloaded. The overload must be

removed before the inverter can be manually restarted by reseting the

on/off switch. Resistive loads are the easiest for the MAXX 400 SST to run.

However, larger resistive loads, such as electric stoves or heaters, usually

require more wattage than the MAXX 400 SST can deliver. Inductive loads,

such as TV’s and stereos, require morecurrent to operate than do resistive

loads of the same wattage rating. Induction motors, as well as some

televisions, may require 2 to 6 times their wattage rating to start up. The

most demanding in this category are those that start under load, such as

compressors and pumps. Testing is the only definitive way to determine

whether a specific load can be started and how long it can run. The unit

will simply shut down if it is overloaded. To restart the unit after a shutdown

due to overloading, remove the overload and reset the on/off switch.

CAUTION:

This inverter will not operate high wattage appliances or 

equipment that produce heat, such as hair dryers, microwave ovens

and toasters.

5.2  

BATTERY OPERATING TIME

With a typical vehicle battery, a minimum operating time of 2 to 3 hours

can be expected. In most instances, 5 to 10 hours of operating time is 

achievable. However, Vector recommends that the operator start the vehicle

Summary of Contents for Maxx SST VEC024

Page 1: ...AD AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS PLUS YOUR VEHICLE S BATTERY MANUFACTURER GUIDELINES FAILURE TO DO SO COULD RESULT IN INJURY AND OR PROPERTY DAMAGE 4140 SW 28TH...

Page 2: ...C plug connections and ring terminal connections 4 This is not a toy keep away from children CAUTIONS 1 Do not use with positive ground electrical systems the majority of modern automobiles RVs trucks...

Page 3: ...ION 6 4 1 Power Source Requirements 6 7 4 2 Connection to Power Source 7 8 4 3 Connection to Load 8 9 4 4 Placement of Inverter 9 5 OPERATING TIPS 10 5 1 Rated Versus Actual Current Draw of Equipment...

Page 4: ...start up currents from large inductive loads could shut down the inverter Three major features are incorporated in SST First gradual voltage ramp upduring inverter start up This eliminates failed col...

Page 5: ...t converts the high voltage DC into 110 volts 60 Hz AC The DC to DC converter stage uses modern high frequency power conversion techniques that have replaced the bulky transformers found in less techn...

Page 6: ...voltage under the assumption that the waveform measured will be a pure sine wave These meters will not read the RMS voltage of a modified sine wave correctly They will read about 20 to 30 volts low wh...

Page 7: ...volt DC plug firmly into the 12 volt DC socket of a vehicle or other DC power source CAUTION Connect directly to power source when operating above 175 watts NOTE Most automobile 12 volt DC circuits us...

Page 8: ...he positive terminal of the DC source battery 4 Connect a length of wire on one side of the fuse holder or circuit breaker Connect the other end if the wire to the positive terminal of the inverter 5...

Page 9: ...o not use the inverter to recharge items that q can be plugged directly into an AC receptacle This problem does not occur with the majority of battery operated equipment Most of these devices use a se...

Page 10: ...nverter can be manually restarted by reseting the on off switch Resistive loads are the easiest for the MAXX 400 SST to run However larger resistive loads such as electric stoves or heaters usually re...

Page 11: ...SST monitors the following potentially hazardous conditions LOW BATTERY VOLTAGE This condition is not harmful to the inverter but could damage the power source An audible alarm will sound when input...

Page 12: ...emit a buzzing sound from their speakers when operated from the MAXX 400 SST power inverter This occurs because the power supply in the electronic device does not adequately filter the modified sine w...

Page 13: ...alarm Bad connection or wiring Tighten all DC sounds continuously connections Low battery Low battery voltage Recharge battery alarm sounds Remove load from inverter while recharging battery Motorize...

Page 14: ...You may also contact us by visiting our website www vectormfg com 10 SPECIFICATIONS Output Connection Dual North American Standard Receptacles Output Voltage Approx 110 volt AC RMS 60 Hz Output Curre...

Page 15: ...oes not cover accessories bulbs fuses and batteries defects resulting from normal wear and tear including chips scratches abrasions discoloration or fading due to usage or exposure to sunlight acciden...

Page 16: ...2004 VECTOR MANUFACTURING Ltd FT LAUDERDALE FL 33312 MADE IN CHINA VECTOR MANUFACTURING LTD...