background image

9

JUMPER SWITCH 

These fans are designed to run continuously at one of 2 lower speeds fixed at installation using the

jumper switch.

12

14

13

15

ELX1003
Minimum Speed
Jumper 1

ELX1003
Speed 2
Jumper 2

ELX1003DT
ELX1003HDT
Minimum Speed
Jumpers 1 and 3.
To DISABLE delay-on
timer remove Jumper 3

ELX1003DT
ELX1003HDT
Speed 2
Jumpers 2 and 3.
To DISABLE delay-on
timer remove Jumper 3

TRIMMER ADJUSTMENT

To adjust the humidistat and timer trimmers, remove the front cover and cir-
cuit board cover of the fan to access the trimmers. 

The humidistat (HY) can be adjusted between 40% and 90% relative humidity.
Turn clockwise to decrease sensitivity and set at a higher level of relative
humidity.

The timer (TM) is adjustable between 0 and 30 minutes.  Turn the trimmer
clockwise to increase the overrun time, or anti-clockwise to decrease it.

Summary of Contents for ELIX 1003

Page 1: ...d continuous running SAP Appendix Q Eligible 3 models standard timer humidity control for all domestic wet rooms for walls or ceilings Energy Efficient Centrifugal Fan with EC Motor Installation and O...

Page 2: ...people To dispose of the pack aging and the appliance at the end of its useful life refer to current recycling rules The use of any electrical product requires compli ance with some basic rules which...

Page 3: ...ance The product must not be used as an activator for water heaters stoves etc The product must not exhaust into ducts designed to evacuate fumes from combustion in stoves or other combustion powered...

Page 4: ...wall plugs 7 8 Decide whether to have cable access from rear recessed or top surface of fan if from top ensure that included grommet is properly fixed See dia 8 If cable is to come through rear of fan...

Page 5: ...INSTALLATION 1 2 4 5 3 6 6...

Page 6: ...7 8 9 10 7 INSTALLATION...

Page 7: ...1 12 8 INSTALLATION ELXs 3 Speed with Cord WIRING DIAGRAMS ELXs 3 Speed via remote switch N B When installing fans via a remote switch pullcord switch must be left in off position and the cord removed...

Page 8: ...DT Speed 2 Jumpers 2 and 3 To DISABLE delay on timer remove Jumper 3 TRIMMER ADJUSTMENT To adjust the humidistat and timer trimmers remove the front cover and cir cuit board cover of the fan to access...

Page 9: ...the fan and disconnect it from the main power supply The filter can be easily removed and carefully washed The front cover can be cleaned with a dry cloth or soft brush The fan must not come into cont...

Page 10: ...Road Cressex Business Park High Wycombe Buckinghamshire HP12 3RH Tel 44 0 1494 522333 Fax 44 0 1494 522337 Email sales vectaire co uk Web www vectaire co uk Vectaire Ltd reserves the right to alter s...

Reviews: