3.0 INSTALLATION & SAFETY
3.1 SITE SELECTION
The furnace should be placed on a heat resistant surface in a well
ventilated room. Do not mount the furnace on an inflammable
surface.
There must be at least 6 inches of space around the furnace to
allow adequate ventilation.
Ensure the furnace is placed in a way it can easily be turned off or
disconnected from the electrical supply.
If the furnace is to be used to heat materials that give off fumes it is
recommended to have an extraction hood above the furnace.
3.2
ELECTRICAL CONNECTION
Connection To Mains Supply
Furnace Voltage is 230 Volts, single Phase.
Connect to a 35 amp supply using suitable cable.