background image

21

©Vecow EMBC-5000 User Manual  

GETTING TO KNOW YOUR EMBC-5000

Pin No.

Signal Name

Pin No.

Signal Name

51

Ground

52

CLKREQ#

49

PETp0

50

PERST#

47

PETn0

48

NC

45

Ground

46

NC

43

PERp0

44

NC

41

PERn0

42

NC

39

Ground

40

NC

37

PETp1/USB3.1-TX+

38

DEVSLP

35

PETp1/USB3.1-TX-

36

UIM-PWR

33

Ground

34

UIM-DATA

31

PETp1/USB3.1-RX+

32

UIM-CLK

29

PETp1/USB3.1-RX-

30

UIM-RESET

27

Ground

28

NC

25

NC

26

NC

23

NC

24

NC

21

NC

22

NC

20

NC

Mechanical Key

11

Ground

9

USB-

10

LED_1#

7

USB+

8

W_DISABLE1

5

Ground

6

FULL_CARD_PWR_OFF/ON

3

Ground

4

3.3V

1

NC

2

3.3V

Summary of Contents for EMBC-5000 Series

Page 1: ...USER Manual USER Manual 1 0 0 Edition 20210318 Intel Core i7 i5 i3 SoC Tiger Lake UP3 3 5 Single Board Computer 1GigELAN 2 5GGigELAN 410GUSB 4COM SUMITA B TPM IgnitionControl EMBC 5000...

Page 2: ...ii Vecow EMBC 5000 User Manual Version Date Page Description Remark 1 00 2021 03 18 All Official Release Record of Revision...

Page 3: ...o frequency energy and if it is not installed and used in accordance with the instruction manual it may cause harmful interference to radio communications Operation of this equipment in a residential...

Page 4: ...E EMBC 5000 3 5 Embedded Single Board Computer onboard Intel Core i7 1185G7E Processor Tiger Lake UP3 DDR4 SO DIMM 1 GigE LAN 2 5GigE LAN 2 10G USB 6 USB 2 0 4 COM RS 232 422 485 2 SATA 9V to 55V DC i...

Page 5: ...13Q1009 0DA COM Port Cable 61 1300011 100 SATA Data Cable 61 13P0430 08A SATA Power Cable Heat Sink Heat Sink for EMBC 5000 Series Heat Spreader Heat Spreader for EMBC 5000 Series 61 13T10LM 3CG Audio...

Page 6: ...nsion 10 1 5 1 Dimensions of EMBC 5000 10 1 5 2 Dimensions of Heat Spreader 10 1 5 3 Dimensions of Heat Sink 11 1 5 4 Dimensions of MB Heat Spreader 11 1 5 5 Dimensions of MB Heat Sink 12 CHAPTER 2 GE...

Page 7: ...ain Manu 47 4 3 Advanced Functions 47 4 4 Chipset Functions 60 4 5 Security 67 4 6 Boot Functions 69 4 7 Save Exit 70 APPENDIX A GPIO GUIDE 71 APPENDIX B Software Functions 74 APPENDIX C RAID Function...

Page 8: ...al channel 16 bit LVDS display interfaces support triple independent displays and up to 8K resolution 4 USB ports support up to 10Gbps SuperSpeed data delivery 1 GigE LAN 2 5G GigE LAN 4 COM RS 232 42...

Page 9: ...ces up to 8K resolution Multiple USB supports up to 10Gbps data transfer 1 Independent 2 5GigE LAN supports Intel Time Sensitive Networking TSN for real time data synchronization 1 GigE LAN supports i...

Page 10: ...GigE LAN supports iAMT LAN2 Intel I225 IT supports 2 5 GigE LAN Audio Audio Codec Realtek ALC888S VD 7 1 Channel HD Audio Audio Interface 1 Mic in 1 Line out Storage SATA 2 SATA III 6Gbps M 2 1 M 2 K...

Page 11: ...supports TPM 2 0 SPI interface Watchdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU ove...

Page 12: ...orts iAMT LAN2 Intel I225 IT supports 2 5 GigE LAN Audio Audio Codec Realtek ALC888S VD 7 1 Channel HD Audio Audio Interface 1 Mic in 1 Line out Storage SATA 2 SATA III 6Gbps M 2 1 M 2 Key B 2260 Sock...

Page 13: ...supports TPM 2 0 SPI interface Watchdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU ove...

Page 14: ...orts iAMT LAN2 Intel I225 IT supports 2 5 GigE LAN Audio Audio Codec Realtek ALC888S VD 7 1 Channel HD Audio Audio Interface 1 Mic in 1 Line out Storage SATA 2 SATA III 6Gbps M 2 1 M 2 Key B 2260 Sock...

Page 15: ...supports TPM 2 0 SPI interface Watchdog Timer Reset 1 to 255 sec min per step Smart Management Wake on LAN PXE supported HW Monitor Monitoring temperature voltages Auto throttling control when CPU ove...

Page 16: ...BC 5000 User Manual GENERAL INTRODUCTION 1 4 Supported CPU List Processor No Cores TDP Cache Max Frequency ECC Memory Intel Core i7 1185G7E 4 15W 12M Up to 4 4GHz N Intel Core i5 1145G7E 4 15W 8M Up t...

Page 17: ...cal Dimension 1 5 1 Dimensions of EMBC 5000 146 0 5 75 85 7 3 38 5 3 0 21 77 7 3 06 50 2 1 98 5 1 0 20 102 0 4 02 19 0 0 75 55 2 2 17 85 7 3 38 73 7 2 90 7 6 0 30 17 9 0 71 Unit mm inch 1 5 2 Dimensio...

Page 18: ...ION 1 5 3 Dimensions of Heat Sink 150 4 5 92 50 2 1 98 85 7 3 38 106 1 4 18 50 2 1 98 85 7 3 38 22 7 0 89 22 7 0 89 73 7 2 90 9 7 0 38 25 2 0 99 Unit mm inch 1 5 4 Dimensions of MB Heat Spreader 148 0...

Page 19: ...12 Vecow EMBC 5000 User Manual GENERAL INTRODUCTION 1 5 5 Dimensions of MB Heat Sink 43 2 1 70 148 0 5 83 103 8 4 09 21 2 0 84 Unit mm inch...

Page 20: ...R EMBC 5000 2 1 Packing List Item Description Qty 1 EMBC 5000 3 5 Embedded Single Board Computer 1 2 Driver User Manual DVD 1 3 Cable Kit COM Port Cable COM Screw 4 40 L 5mm SATA Data Cable SATA Power...

Page 21: ...45 143 1 2 1 146 144 260 2 20 19 BZ1 JP3 SW1 JPWBTN JSTATUS BAT JP4 SYS_FAN1 DIMM1 CN5 JP6 JP7 DP_CN1 DP_CN2 CN6 CN7 CN8 M2B_CN1 LAN2_CON LAN1_CON JPS1 JRESET JHDD JSEL_DIO JDIO1 CN4 JUSB1 JUSB2 M2E_C...

Page 22: ...d top panel The pinouts of Miscellaneous port are listed in following table Group Pin No Description JPWBTN 1 GND 2 FP_PWR_BTN_IN JRESET 1 GND 2 FP_RST_BTN_N JSTATUS 1 PWR_LED_N 2 PWR_LED_P JHDD 1 HDD...

Page 23: ...1 A_z_MIC1 L 2 GND_A 3 A_z_MIC1 R 4 GND_EARTH 5 A_z_LINEO R 6 A_z_LINEI R 7 F_IO_SENSE 8 GND_EARTH 9 A_z_LINEO L 10 A_z_LINEI L 1 2 5 10 There are three audio connectors mic in line in and line out i...

Page 24: ...nd a USB connector on the other The pin assignments of JUSB1 and JUSB2 are listed in the following table Pin No Definition Pin No Definition 1 USB_VCC 2 USB_VCC 3 USB_VCC 4 USB_D_4N 5 USB_D_4P 6 USB_D...

Page 25: ...RVED PERp1 56 NC 57 GND 54 NC 55 PEWAKE0 I O 0 3 3V 52 PERST03 I 0 3 3V 53 CLKREQ0 I O 0 3 3V M 2 key E connector is suitable for applications that use wireless connectivity including Wi Fi Bluetooth...

Page 26: ...EFCLKp0 44 NC 45 GND 42 NC 43 PETn0 40 NC 41 PETp0 38 NC 39 GND 36 NC 37 PERn0 34 NC 35 PERp0 32 NC 33 GND Module Key Module Key Module Key Module Key Module Key Module Key Module Key Module Key 22 NC...

Page 27: ...NC 55 REFCLKp 56 NC 53 REFCLKn 54 PEWAKE M 2 key B connector is suitable for applications that use wireless connectivity including LTE 5G module and NVMe SSD BW PCIex2 that types include 2260 3042 305...

Page 28: ...C 43 PERp0 44 NC 41 PERn0 42 NC 39 Ground 40 NC 37 PETp1 USB3 1 TX 38 DEVSLP 35 PETp1 USB3 1 TX 36 UIM PWR 33 Ground 34 UIM DATA 31 PETp1 USB3 1 RX 32 UIM CLK 29 PETp1 USB3 1 RX 30 UIM RESET 27 Ground...

Page 29: ...wire RS 485 RS 485 w z auto flow control 1 10 The pin assignments are listed in the following table Serial Port Pin No RS 232 RS 422 5 wire RS 422 9 wire RS 485 3 wire 1 2 3 4 1 GND_EARTH GND_EARTH G...

Page 30: ...5 3 1 39 40 10 9 1 18 4 13 5 14 L4 G R1 R2 O L3 1 2 L2 2 10 20 19 1 9 1 4 1 3 259 145 143 1 2 1 146 144 260 2 20 19 CN7 2 2 11 CN8 External USB 3 2 Connector There are 2 USB 3 2 Gen2 connections avail...

Page 31: ...nection for example a hub or a switch Moreover both LAN1 and LAN2 support Wake on LAN and Pre boot functions The pinouts of LAN1_CON and LAN2_CON are listed as follow Pin No 10 100MBps 1000MBps 2500MB...

Page 32: ...the Left top corner of LAN1_CON will keep twinkling off when Ethernet data packets are being transmitted received LED Location LED Color 10Mbps 100Mbps 1000Mbps Right Green Orange Off Solid Orange So...

Page 33: ...ignments of LVDS are listed in the following table Pin No Definition Pin No Definition 1 PANEL_VDD 2 TXO0 3 PANEL_VDD 4 TXO0 5 PANEL_VDD 6 TXO1 7 GND 8 TXO1 9 GND 10 TXO2 11 GND 12 TXO2 13 GND 14 TXOC...

Page 34: ...3 5 14 L4 G R1 R2 O L3 1 2 L2 2 10 20 19 1 9 1 4 1 3 259 145 143 1 2 1 146 144 260 2 20 19 DP_CN1 DP_CN2 2 2 15 CN1 DC Power input EMBC 5000 supports 9V to 55V DC power input by wire to board connecto...

Page 35: ...and 12V Up to 2A currents to the hard drive or SSD The pin assignments of J3 is listed in the following table Pin No Definition Pin No Definition 1 12V 2 GND 3 GND 4 5V 1 4 Y L1 1 R10 R9 7 1 7 1 6 A2...

Page 36: ...USB_2 24 LPC_AD0 25 USB_2 26 LPC_AD1 27 5V 28 LPC_AD2 29 USB_1 30 LPC_AD3 31 USB_1 32 LPC_FRAME 33 5V 34 SERIRQ 35 USB_0 36 Reserved 37 USB_0 38 CLK_33MHz 39 GND 40 GND 41 A_PET_P0 42 A_PER_P0 43 A_P...

Page 37: ...1 C_CLKN 12 B_CLKN 13 CPRSNT C_PE_CLKREQ 14 GND 15 C_PET_P0 16 C_PER_P0 17 C_PET_N0 18 C_PER_N0 19 GND 20 GND 21 C_PET_P1 22 C_PER_P1 23 C_PET_N1 24 C_PER_N1 25 GND 26 GND 27 C_PET_P2 28 C_PER_P2 29 C...

Page 38: ...ax 3 Fan speed sensor 4 Fan PWM 1 4 Y L1 1 R10 R9 7 1 7 1 6 A2 A52 B2 B52 10 10 10 10 A1 A51 10 B1 B51 3 1 10 1 10 1 1 4 2 10 1 L2 1 1 1 1 7 3 1 Y L1 R10 R9 10 1 1 L4 G O L3 R1 R2 2 1 1 8 4 5 3 1 39 4...

Page 39: ...85 SIO_GPO75 7 SIO_GPI86 SIO_GPO76 8 SIO_GPI87 SIO_GPO77 9 VDIO VDIO 10 GND GND 1 10 Y L1 1 R10 R9 7 1 7 1 6 A2 A52 B2 B52 10 10 10 10 A1 A51 10 B1 B51 3 1 10 1 10 1 1 4 2 10 1 L2 1 1 1 1 7 3 1 Y L1 R...

Page 40: ...9 1 4 1 3 259 145 143 1 2 1 146 144 260 2 20 19 JP3 Pin assignment as the following table Pin No Definition Pin No Definition 1 FP_PWR_BTN_P 2 GND 3 IGNITION 4 GND 4 1 2 2 24 M2B_SIM1 Nano SIM Card S...

Page 41: ...ns and a small metal clip often protected by a plastic cover that slides over the pins to connect them To close a jumper you connect the pins with the clip To open a jumper you remove the clip Sometim...

Page 42: ...2 B2 B52 10 10 10 10 A1 A51 10 B1 B51 3 1 10 1 10 1 1 4 2 10 1 L2 1 1 1 1 7 3 1 Y L1 R10 R9 10 1 1 L4 G O L3 R1 R2 2 1 1 8 4 5 3 1 39 40 10 9 1 18 4 13 5 14 L4 G R1 R2 O L3 1 2 L2 2 10 20 19 1 9 1 4 1...

Page 43: ...8 4 13 5 14 L4 G R1 R2 O L3 1 2 L2 2 10 20 19 1 9 1 4 1 3 259 145 143 1 2 1 146 144 260 2 20 19 JP4 2 3 5 JP6 Power Selection for EXT and INT USB 3 2 Gen2 USB 2 0 Ports Pin No Definition 1 2 5V Standb...

Page 44: ...y period 2 4 1 Adjust Ignition Control Modes EMBC 5000 series provides 16 modes of different power on off delay periods adjustable via SW1 switch The default rotary switch is set to 0 inATX AT power m...

Page 45: ...10 seconds 4 No delay 20 seconds 5 5 seconds 30 seconds 6 5 seconds 60 seconds 7 5 seconds 90 seconds 8 5 seconds 30 minutes 9 5 seconds 1 hour A 10 seconds 2 hours B 10 seconds 4 hours C 10 seconds 6...

Page 46: ...to the picture blow to simulate ignition signal input controlled by a latching switch Note 1 DC power source and IGN share the same ground 2 EMBC 5000 supports 9V to 55V wide range DC power input in A...

Page 47: ...40 Vecow EMBC 5000 User Manual SYSTEM SETUP SYSTEM SETUP 3 1 Installing Heat Spreader 3 Step 1 Place the motherboard and heat sink in position Step 2 Fasten six PH M3x4 screws circled in red...

Page 48: ...41 Vecow EMBC 5000 User Manual SYSTEM SETUP 3 2 Installing Heat Sink Step 1 Place the motherboard and heat sink in position Step 2 Fasten six PH M3x4 screws circled in red...

Page 49: ...42 Vecow EMBC 5000 User Manual SYSTEM SETUP 3 3 Installing DDR4 SO DIMM Module Step 1 Install DDR4 RAM module into SO DIMM slot Step 2 Make sure the RAM module is locked by the memory slot...

Page 50: ...PH M3x4L screw 3 4 Installing M 2 3 4 1 Key E 2230 Key B 2260 Step 1 Install M 2 into the M 2 slot 3 4 2 Key B 3042 Step 1 Install M 2 into the M 2Tary and fasten one PH M3x4L screw Step 2 Install Mi...

Page 51: ...Vecow EMBC 5000 User Manual SYSTEM SETUP 3 4 3 Key B 3052 Step 1 Install M 2 into the M 2Tary and fasten one PH M3x4L screw Step 2 Install Mini PCIe card into the Mini PCIe slot and fasten one M3 scr...

Page 52: ...45 Vecow EMBC 5000 User Manual SYSTEM SETUP 3 5 Installing SIM Card Step 1 Install SIM card into to the SIM card slot...

Page 53: ...TUP 4 BIOS SETUP 4 1 BIOS Setting BIOS provides an interface for users to check and change system configuration The BIOS setup program is accessed by pressing the Del key when POST display output is s...

Page 54: ...tem date and system time System Date Set the date Use tab to switch between date elements System Time Set the time Use tab to switch between time elements Figure 4 2 BIOS Main Menu Figure 4 3 BIOS Adv...

Page 55: ...al hardware capabilities provided by Vanderpool Technology Active Processor Cores Number of cores to enable in each processor package Hyper threading Enabled or Disabled Hyper Threading Technology AES...

Page 56: ...MSR 1FC bit 20 Intel Speed shift Technology Enable Disable Intel Speed Shift Technology support Enabling will expose the CPPCv2 interface to allow for hardware controlled P states Turbo Mode Enable D...

Page 57: ...ME will be put into ME Temporarily Disabled Mode Manageability Features State Enable Disable Intel R Manageability features NOTE This option disables enables Manageability Features support in FW To d...

Page 58: ...st of settings and their current state are displayed below when Intel R TCC mode is enabled IO Fabric Low Latency Enable or Disable IO Fabric Low Latency This will turn off some power management in th...

Page 59: ...e not effective with some OS ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed S3 Video Repost Enable or Disable S3 Video Repost 4 3 6 ACPI...

Page 60: ...4 3 8 Super IO Settings Serial Port 1 Configuration Set Parameters of Serial Port 1 COM1 Serial Port 2 Configuration Set Parameters of Serial Port 2 COM2 Serial Port 3 Configuration Set Parameters of...

Page 61: ...ll Speed if Smart Fan Support is Disabled Smart Fan Mode Default Using the default smart fan table User Setting parameters by user Start Temperature Temperature Limit value of Fan Start Degree C Range...

Page 62: ...Both computers should have the same or compatible settings Legacy Console Redirection Settings Legacy Console Redirection Settings Serial Port for Out of Band management Windows Emergency Management S...

Page 63: ...ble Automatic Acoustic Management 4 3 12 Acoustic Management Configuration Figure 4 3 12 Acoustic Management Settings BME DMA Mitigation Re enable Bus Master Attribute disabled during Pci enumeration...

Page 64: ...d be claimed by XHCI driver USB Mass Storage Driver Support Enable disable USB Mass storage driver support USB transfer time out The time out value for control bulk and Interrupt transfers Device rese...

Page 65: ...action on INT19 trapping by option ROM IMMEDIATE execute the trap right away POSTPONED execute the trap during legacy boot Boot option filter This option controls Legacy UEFI ROM s priority Network Co...

Page 66: ...able disable IPv4 PXE boot support Ipv4 HTTP Support Enable disable IPv4 HTTP boot support Ipv6 PXE Support Enable disable IPv6 PXE boot support Ipv6 HTTP Support Enable disable IPv6 HTTP boot support...

Page 67: ...Figure 4 4 BIOS Chipset Menu 4 4 1 System Agent SA Configuration VT d VT d capability Above 4GB MMIO BIOS assignment Enable Disable above 4GB MemoryMappedIO BIOS assignment This is disabled automatic...

Page 68: ...r Hybrid Gfx Internal Graphics Keep IGFX enabled based on the setup options GTT Size Select the GTT size Aperture Size Select the aperture size Note Above 4GB MMIO BIOS assignment is automatically ena...

Page 69: ...SA PCI Express Configuration PCI Express Clock Gating PCI Express Clock Gating Enable Disable for each root port PCI Express Power Gating PCI Express Power Gating Enable Disable for each root port Co...

Page 70: ...power is re applied after a power failure G3 state Figure 4 4 2 PCH IO Settings 4 4 2 1 PCI Express Configuration DMI Link ASPM Control The control of Active State Power Management of the DMI Link Na...

Page 71: ...M configuration to enable disable the storage features Aggressive LPM Support Enable PCH to aggressively enter link power state Options for each SATA port Port n Enable or disable SATA port Hot Plug D...

Page 72: ...em power on by ignition pin Delay On Timer Seconds The delay time after user trigger ignition on signal Seconds Delay Off Timer Seconds The delay time after user trigger ignition off signal Seconds Fo...

Page 73: ...5000 User Manual BIOS SETUP 4 4 4 LVDS Configuration The LVDS Configuration option will be present if LVDS panel is connected on system LCD Panel Type Select LCD Panel Resolution Figure 4 4 4 LVDS Pa...

Page 74: ...Vecow EMBC 5000 User Manual BIOS SETUP Administrator Password Set administrator password User Password Set user password Secure Boot Secure Boot coonfiguration 4 5 Security Figure 4 5 BIOS Security Me...

Page 75: ...is gray do power cycle to enable the option again 4 5 2 Security Boot Figure 4 5 2 Security Boot Settings Secure Boot Secure Boot feature is Active if Secure Boot is Enabled Platform Key PK is enrolle...

Page 76: ...f seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state Quiet Boot Enables or disables Quiet Boot option Boot Option x S...

Page 77: ...set Reset system setup without saving any changes Save Changes Save Changes done so far to any of the setup options Discard Changes Discard Changes done so far to any of the setup options Default Opti...

Page 78: ...ition 1 GPIO 0 1 GPIO 8 2 GPIO 1 2 GPIO 9 3 GPIO 2 3 GPIO 10 4 GPIO 3 4 GPIO 11 5 GPIO 4 5 GPIO 12 6 GPIO 5 6 GPIO 13 7 GPIO 6 7 GPIO 14 8 GPIO 7 8 GPIO 15 9 VDIO 9 VDIO 10 GND 10 GND Y L1 1 R10 R9 7...

Page 79: ...and Uninstall_32 bat and Uninstall_64 bat Uninstallation for driver Run batch file as Administrator Make sure Windows version before installation Header folders include head file for software develop...

Page 80: ...73 Vecow EMBC 5000 User Manual Appendix A A 3 Sample Execute demo tool Sample as shown below Windows Linux Vecow_DIO Vecow_DIO_loopback Vecow_POE Vecow_WDT...

Page 81: ...ot match BOOL get_IO1_configuration BYTE Iso BYTE DI_mode BYTE DO_ mode WORD Mask BOOL get_IO2_configuration BYTE Iso BYTE DI_mode BYTE DO_ mode WORD Mask Get DIO configuration by variable Isolate_Typ...

Page 82: ...imal bitmask only for Non Isolated DIO GPIO 1 Output 0 Input Return TRUE 1 Success FALSE 0 Fail Initial error or hardware problem BOOL get_DIO1 BYTE DO_data BYTE DI_data BOOL get_DIO2 BYTE DO_data BYT...

Page 83: ...error or hardware problem BOOL get_WDT DWORD WDT Get watchdog timer setup WDT watchdog timer setup Unit second Range 0 65535 sec 1093 65535 min 65580 3932100 sec Return TRUE 1 Success FALSE 0 Fail In...

Page 84: ...nterprise version both need to load the IRST driver so Windows can detect a storage drive The steps below are required to set up and configure HW BIOS supported systems for Intel RST storage managemen...

Page 85: ...the setting on Enable VMD Global Mapping to Enabled 4 Save Changes and Reset When asked if you want to save changes click Yes 5 Access BIOS menu again select Intel R Rapid Storage Technology 6 Select...

Page 86: ...allation as an example 1 Please download Intel Rapid Storage Technology IRST driver Download Link from Intel website Intel Rapid Storage Technology Driver Installation Software with Intel Optane Memor...

Page 87: ...udes the following files 5 Select Windows 10 USB drive to enter Windows 10 setup interface Follow the installation instruction the system should enter the storage setting interface the bottom of the s...

Page 88: ...81 Vecow EMBC 5000 User Manual Appendix C 6 Click on Browse icon 7 Select Intel VMD driver folder which has been saved in then click on OK to continue the process...

Page 89: ...stall the Intel VMD driver after the process is complete you will see the list of all drives and partitions on your computer You can choose to Refresh Format Delete the available drives then click on...

Page 90: ...oftware with Intel Optane Memory driver C 4 To Install Intel Rapid Storage Technology Driver Installation Software with Intel Optane Memory Software You can get the software on the driver CD Also you...

Page 91: ...emory and Storage Management application user interface is a Microsoft Store app It provides users with monitoring and management capabilities for the Intel Rapid Storage Technology Intel RST storage...

Page 92: ...e The volume will be shown in the OS related applications and it will display Pass through SATA and PCIe disks Empty SATA ports RAID volumes and Intel Optane memory volumes The following guide link ca...

Page 93: ...of the member drives and will let you know which port has the failed drive C 9 Recovery and Auto Rebuild When Use the SAME RAID HDD SSD Open the Intel Optane Memory and Storage Management User Interf...

Page 94: ...Mouse HP G1K28AA USB 3 USB 3 0 USB Flash ADATA 3 0 16GB USB 4 USB 3 0 USB Flash ADATA 3 0 16GB USB 5 USB 2 0 USB Flash Kingston 3 0 16GB USB 6 USB 2 0 USB Flash Kingston 3 0 16GB SATA 0 Transcend SATA...

Page 95: ...7 1185G7E 9V 0 380A 03 42W 0 399A 03 59W 1 870A 16 83W 12V 0 328A 03 94W 0 317A 03 81W 1 575A 18 90W 24V 0 167A 04 00W 0 207A 04 96W 0 779A 18 69W 55V 0 116A 06 36W 0 144A 07 93W 0 409A 22 50W CPU Pow...

Page 96: ...1145G7E 9V 0 300A 02 70W 0 423A 03 81W 2 077A 18 69W 12V 0 236A 02 83W 0 334A 04 01W 1 508A 18 10W 24V 0 155A 03 73W 0 217A 05 21W 0 772A 18 52W 55V 0 126A 06 91W 0 145A 07 96W 0 398A 21 90W CPU Powe...

Page 97: ...est Temp Celsius innodisk 32G DDR4 3200 SO DIMM M4S0 BGS2OCEM H03 25 C innodisk 32G DDR4 3200 SO DIMM M4S0 BGS2O5EM H03 25 C innodisk 16G DDR4 3200 SO DIMM M4S0 AGS1O5EM H03 25 C SL Link 16GB DDR4 320...

Page 98: ...64GSSD370 64GB innodisk 3MG2 P DGS25 64GD81BC1QC 64GB 3TE7 DES25 B56DK1GC3QL H03 256GB Kingston SA400S371120G 120GB SUV400S37 120GB Intel SSD E 5400s SSDSC2KR120H6 120GB MEMXPRO M3A MI3MA1212802WN 128...

Page 99: ...fications are subject to change without prior notice No part of this publication may be reproduced in any form or by any means electric photocopying or recording without prior authorization from the p...

Reviews: