100
©Vecow IVH-7700 User Manual
Appendix E
E
APPENDIX E : Ignition Control
Power-on Delay
case 1:Count=5;break;
case 2:Count=10;break;
case 3:Count=15;break;
case 4:Count=20;break;
case 5:Count=25;break;
case 6:Count=30;break;
case 7:Count=40;break;
case 8:Count=50;break;
case 9:Count=60;break;
case 10:Count=300;break;
case 11:Count=600;break;
case 12:Count=900;break;
case 13:Count=1200;break;
case 14:Count=1800;break;
case 15:Count=3600;break;
Power-off Delay
case 1:Count=20;
case 2:Count_1=1;break;
case 3:Count_1=5;break;
case 4:Count_1=10;break;
case 5:Count_1=20;break;
case 6:Count_1=30;break;
case 7:Count_1=50;break;
case 8:Count_1=1;
case 9:Count_1=2;
case 10:Count_1=3;
case 11:Count_1=6;
case 12:Count_1=9;
case 13:Count_1=12;
case 14:Count_1=15;
case 15:Count_1=18;
//5Sec
//10Sec
//15Sec
//20Sec
//25Sec
//30Sec
//40Sec
//50Sec
//60Sec
//5min
//10min
//15min
//20min
//30min
//1hr
//20sec
//1min
//5min
//10min
//20min
//30min
//50min
//1Hr
//2Hr
//3Hr
//6Hr
//9Hr
//12Hr
//15Hr
//18Hr