background image

Artisan Technology Group 

is your source for quality 

new and certified-used/pre-owned equipment

• 

FAST SHIPPING AND 

DELIVERY

• 

TENS OF THOUSANDS OF 

IN-STOCK ITEMS

•  EQUIPMENT DEMOS
• 

HUNDREDS OF 

MANUFACTURERS 

SUPPORTED

•  LEASING/MONTHLY

 

RENTALS

•  ITAR CERTIFIED

           

SECURE ASSET 

SOLUTIONS

SERVICE CENTER REPAIRS

Experienced engineers and technicians on staff 

at our full-service, in-house repair center

WE BUY USED EQUIPMENT

Sell your excess, underutilized, and idle used equipment 

We also offer credit for buy-backs and trade-ins

www.artisantg.com/WeBuyEquipment

                        

REMOTE INSPECTION

Remotely inspect equipment before purchasing with 

our interactive website at

 

www.instraview.com

LOOKING FOR MORE INFORMATION? 

Visit us on the web at

 

www.artisantg.com

    

for more 

information on price quotations, drivers, technical 

specifications, manuals, and documentation

Contact us:

 

 

(888) 88-SOURCE  |  [email protected]  |  www.artisantg.com

SM

View

Instra

Summary of Contents for 6151

Page 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Page 2: ...6151 Industrial Computer Product Data Installation Instructions User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...ns Permission from the local power authority should be obtained before connecting this equipment directly to public mains The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation cannot assume responsibility or liability for actual use based on the examples a...

Page 4: ...pment The purchaser voids his title to the benefits of this warranty that does not treat the equipment in accordance with Rockwell Automation s recommendations or in accordance with good industry practice The equipment described in this document generates uses and emits radio frequency energy The equipment has been tested and found to comply with FCC Rules Part 15 subpart J for Class A computing d...

Page 5: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 6: ...ting Started 2 1 Installing the 6151 2 1 Physical Dimensions 2 3 Panel Cutout 2 4 Connecting AC Power 2 5 Controls Indicators 2 6 LCD Controls 2 8 Communication Setups 2 12 Maintenance Chapter 3 Preparation for Shipment 3 1 Cleaning 3 2 Replacing the Battery 3 2 Troubleshooting and Specifications Chapter 4 Troubleshooting 4 1 Specifications 4 1 Table of Contents Table of Contents Table of Contents...

Page 7: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 8: ...ide for the 6151 Industrial Computer It gives an overview of the system and describes procedures you use to install the 6151 Computer in a panel or enclosure install and remove system components run the system troubleshoot the system The following conventions are used throughout this manual Bulleted lists such as this one provide information not procedural steps Numbered lists provide sequential s...

Page 9: ...ments Refer to the Rockwell Automation Allen Bradley Internet site at http www ab com for local contact information Technical Product Assistance If you need to contact Allen Bradley for technical assistance please review the information in the Troubleshooting section first Then call your local Allen Bradley representative or contact Allen Bradley technical support at 440 646 5800 For additional pr...

Page 10: ...igned for industrial use Special BIOS controlled resolution of 656 x 496 Numeric and Cursor Keypad 33 key control keypad 10 front panel function keys Function Keys Built in function keys F1 F10 Access Panel Encloses the keyboard connector Hard disk LED Power LED Floppy disk drive 8 slot Passive Rear Panel Connector points Two COM Ports One LPT1 Ports for a monitor and keyboard Expansion slots Thum...

Page 11: ...rs are shipped with the following items Computer with integrated LCD with a protective clear polycarbonate shield 1 82 m 6 ft AC power cord optional Interconnect loop through cable for external keyboard Mounting hardware kit package of 16 10 32 lock nuts 16 flat washers and 2 labels Bulletin 6151 Product Data Installation Instructions User Manual CPU Processor Manual Packing List Artisan Technolog...

Page 12: ... unit The mounting studs will accommodate this minimum thickness panel and panels up to 6 35 mm 25 in thick To install the Bulletin 6151 Industrial Computer 1 Confirm that the shipping carton contains a package of 16 10 32 lock nuts and 16 flat washers You will need 14 nuts for installation of Bulletin 6151 2 Refer to the physical dimension drawing See Physical Dimensions and confirm that there is...

Page 13: ...ter or chemical damage to the Bulletin 6151 Industrial Computer or other equipment within the enclosure due to improper installation Important To assure a proper seal be sure to install a nut and washer on each of the mounting studs 14 for Bulletin 6151 8 Remove the protective adhesive sheet from the screen of the Industrial Computer The sheet is designed to prevent scratching of the polycarbonate...

Page 14: ...e 1 Bulletin 6151 Industrial Monitor Physical Dimensions Note Be sure to allow at least 76 2 mm 3 00 in depth clearance for cable connections and air flow Physical Dimensions Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 15: ... 4 Installation Instructions Publication 6151 UM001C EN P Figure 2 Panel Cutout for Bulletin 6151 Panel Cutout Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 16: ...e monitor to establish a chassis to earth ground connection Secure one end of a ground strap to the GND point Connect the other end of the ground strap to a good earth ground The ground terminal is an M5 screw ATTENTION Chassis ground must be connected for safe operation of the monitor The AC receptacle on the monitor is a 3 wire type with chassis ground pin and the mating AC cord supplied is a 3 ...

Page 17: ...e runs from the switched outlet on the rear of the computer to the AC power connector for the monitor 5 Connect the plug end of the AC power cord to the mains power supply This is an example of one possible setup for the 6151 Industrial Computers The callouts are described in Table A Figure 3 Back View of One Setup for Bulletin 6151 Industrial Computer configured for AC power Controls Indicators A...

Page 18: ...t for keyboard jumper Monitor Items Fan filter Connector for the optional keyboard Port for keyboard jumper B Fuse for monitor DC units only Ground Screw AC or DC united cable assembly Input Terminal DC units only Figure 4 Example of Front Control Panel Setup for Bulletin 6151 Industrial Computer KEYBOARD CONNECTOR LED LED FLOPPY DISK DRIVE HARD DISK POWER The Hard Disk LED glows green when the ha...

Page 19: ...s Yes to questions Down Up Arrow keys have two functions If the main menu is displayed pressing these keys moves the cursor to desired selection that needs adjusting If a control box is displayed these keys may be used to adjust the value for the control Exit This operation key Records changes made to the selection when the control box for a desired selection is displayed The control box closes an...

Page 20: ...ch key can be set up as you need it for your work The keypads are of embossed membrane design for high reliability and good tactile feedback Function Keys Function keys 1 to 10 act in the same way as the equivalent keys on standard IBM AT keyboards Figure 6 Function Keys Table C Function Key Scan Code Values Keypad Legend Scan Code Hex F1 3B F2 3C F3 3D F4 3E F5 3F F6 40 F7 41 F8 42 F9 43 F10 44 A...

Page 21: ...ENTER Main Pad Enter 1C 9 Number Pad 9 Pg Up 49 SPACE Main Pad Space Bar 20 9 Number Pad 9 Pg Up 49 SPACE Main Pad Space Bar 20 Number Pad 4A SHIFT Main Pad Left Shift 2A 4 Number Pad 4 Left Arrow 4B CTRL Main Pad Left Control 1D 5 Number Pad 5 4C ALT Main Pad Left Alt 38 6 Number Pad 6 Right Arrow 4D HOME Home E0 47 Number Pad 4E Up Arrow E0 48 1 Number Pad 1 End 4F PAGE UP Page Up E0 49 2 Number...

Page 22: ...r Pad 3 Pg Dn 51 Right Arrow E0 4D 0 Number Pad 0 Ins 52 END End E0 4F Number Pad Del 53 Down Arrow E0 50 Number Pad 37 PAGE DOWN Page Down E0 51 ESC Main Pad Escape 01 INS Insert E0 52 DEL Delete E0 53 BACK SPACE Main Pad Back Space 0E PRINT SCREEN Print Screen E0 2A E0 37 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 23: ...nnector at each end Figure 8 Standard VGA Video HD 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 HD15 View looking into the Pin End of the Male connector Table E Standard Cable Construction Monitor HD15 Signal Description Computer HD15 2 Green Video 2 7 Green Video Ground 7 1 Red Video 1 6 Red Video Ground 6 3 Blue Video 3 8 Blue Video Ground 8 5 Composite Sync 5 Not Used 11 Floating ID0 11 12 Floating I...

Page 24: ...n For computers configured with the keyboard option use the 5 pin DIN keyboard cable 1 Connect the female end to the monitor s Keyboard Out connector 2 Connect the male end to the computer s Keyboard connector An IBM AT keyboard may be connected to the front panel 5 pin DIN connector or to the rear panel Keyboard In connector Only one auxiliary keyboard input port can be used at any time If your c...

Page 25: ...t the rear of the unit 2 Unplug the keyboard power and video cables 3 Slide the chassis straight back and out to the stop taking care to support the chassis as it slides free of its rails 4 To remove the computer drawer completely pull it out to the stop and then give it a tug to move it past the catch Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 26: ...removing the computer from the panel or rack Fuses Bulletin 6151 Industrial Computers are equipped with an line fuse to protect the monitor DC unit power supplies have a second line fuse Fuses are accessible from the rear panel Note DC units use a second line fuse Very Fast Acting 3AB rated at 30A 65V DC on the 24V DC power supply To replace a fuse 1 Remove AC power by disconnecting the AC or DC l...

Page 27: ... taken when cleaning a touchscreen or polycarbonate shield that is installed over the screen Abrasive and certain chemical cleaners can easily damage the surface Note For best results cleaning a monitor with the optional antireflective tempered glass display shield a solution of denatured alcohol is recommended to thoroughly clean the display Never use alcoholic or ammoniac cleaners to clean the p...

Page 28: ...faulty cable No keypad communications Keypad cable problem Check for proper cable installation replace suspected faulty cable No touchscreen communications Touchscreen cable problem Check for proper cable installation replace suspected faulty cable Refer to the touchscreen documentation provided for further information Processor Memory Processor Speed MHz 486DX4 133 MHz Memory Options 4M for 486DX...

Page 29: ...6 x 496 Cables AC power cord 1 5 ft Video Cable DC keyboard cable Environmental specifications assume standard configuration excluding diskette drive Temperature Operating 5 C to 50 C Storage 25 C to 60 C Relative Humidity 8 to 80 noncondensing Altitude Operating 0 to 10 000 ft 3 000 m Non Operating 0 to 40 000 ft 12 000 m Vibration Operating 1 0g peak 10 150Hz sine sweep 006in peak peak Non Opera...

Page 30: ...x DC Fuse 250V AC 2 5A 5ST Slo Blo monitor 65V DC 30A 3AB VFA DC option units Safety Electric Shock Fire UL 1950 C UL 1950 recognized component Physical Dimensions 19 0 in W x 12 2 in H x 16 3 in D 483mm x 310mm x 413mm Net Weight 37 lb 17 kg Certifications NEMA 4 12 UL 508 C UL 508 listed EN60950 UL C UL 1950 recognized component CE Artisan Technology Group Quality Instrumentation Guaranteed 888 ...

Page 31: ...4 4 Troubleshooting and Specifications Publication 6151 UM001C EN P Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 32: ...Troubleshooting and Specifications 4 5 Publication 6151 UM001C EN P Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 33: ...International Business Machines Corporation Microsoft is a registered trademark of Microsoft Corporation Microsoft Windows is a trademark of Microsoft Corporation Publication 6151 UM001C EN P 40061 389 01 3 Copyright 2001 Rockwell Automation All rights reserved Printed in USA Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 34: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Reviews: