background image

 

 

 

Veco SpA 

Installation Manual 

Page 3 / 13 

 

1.

 

Introduction 

1.1.

 

General information 

Thank you for purchasing a Climma CWS system! 
This  manual  will  provide  necessary  information  for  the  proper  installation,  operation,  and 
maintenance of your Climma system.  
Climma products are designed and produced to the highest standards and they are all tested in the 
factory. If your Climma system is used according to the guidelines in this manual, it will guarantee 
you trouble free operation for many years. 
If you require assistance, please contact one of our many authorized service centers. To find the 
service center please check our website 

www.veco.net

 or write us at 

[email protected]

 

1.2.

 

System features 

The new Climma C-TOUCH thermostats has been designed to be easy to use and simple, to get the 
best out of your climate control.  

 

Weekly scheduler 

 

Customizable interfaces and colors 

 

Easy interface 

 

Designed for the most used cover plates 

 

Lcd display 2,4’ (320x240 px)

 

 

C-TOUCH  is  compatible  with  Climma  self-contain  Compact  units  (serie  Mk3  and  EF,  with  MK3 
electronic  control)  and  with  Climma  fancoils  (with  Mv8  electronic  control  and  MCON  electronic 
control). 
C-TOUCH  can  fully  replace  Mk3  controls  and Mk2  controls,  considering  that  the  Mk3  and    Mk2 
controls needs a 4 position cutout, while C-Touch only a 3 position. While replacing the control, 
make sure to order the adjusting kit from 4 to 3 positions. 
C-Touch display is also compatible with the following cover plates: 

 

 
The  unit  has  to  be installed by  an  authorized  Climma  service  center  and  in  compliance with  the 
instructions  given  in  this  manual.    A  bad  installation  or  a  misunderstanding  of  the  display 
functioning may result in possible problems and wrong functioning of the system. 

Brand

Serie

Veco Code

Plaque code

Cut on support

BTICINO

LIVINGLIGHT

MPACT001

LNA4803**, LNB4803**, L4803**

Yes

BTICINO

AXOLUTE 

MPACT001

HA4803** / HB4803**

Yes

VIMAR

ARKE'

MPACT001

Arkè 3 position plaque

No

VIMAR

EIKON EVO

MPACT001

Eikon 3 position plaque (BS type excluded)

Yes

VIMAR

EIKON EXE'

MPACT001

Eikon 3 position plaque (BS type excluded)

Yes

VIMAR

PLANA

MPACT001

Plana 3 position plaque

No

BTICINO

AIR (LIVINGLIGHT AIR)

MPACT101

LNC4803** 

Yes

BTICINO

AIR (AXOLUTE AIR)

MPACT201

HW4803**

Yes

VIMAR

IDEA

MPACT301

167*3 (vimar Idea 3 modules)

No

Summary of Contents for Climma C-TOUCH

Page 1: ...Installation usage and maintenance manual C TOUCH CONTROL Rev 2 230511...

Page 2: ...4 2 Installation 5 2 1 Climma C Touch display location 5 1 1 Cut out and display mounting 5 1 2 Battery 6 1 1 Battery change 6 2 Operating instructions 7 2 1 Home screen and symbols 7 2 2 Initial sett...

Page 3: ...e Mk3 and EF with MK3 electronic control and with Climma fancoils with Mv8 electronic control and MCON electronic control C TOUCH can fully replace Mk3 controls and Mk2 controls considering that the M...

Page 4: ...he recommendations of this manual are solely the responsibility of the unit operator before installation and maintenance operations disconnect the unit from the power supply failure to comply may resu...

Page 5: ...erature therefore it s suggested to install it at the mid height of the cabin on an inside wall that provides a good air circulation The Climma C Touch display should not be installed in a position wh...

Page 6: ...d battery type is CR2032 The battery is used only when the panel is powered off the battery will last for a minimum of 2 years when powered off When the battery dies you need to change it and then res...

Page 7: ...ss to turn ON or OFF the fan Automatic mode when fan is in Auto mode the A is displayed on the screen 6 The bars are showing the actual fan speed through blue or red in case of heating bars 7 The symb...

Page 8: ...has to be set depending on the system it needs to control At first startup please select the language it may be changed also later on from the Main Men The display will automatically recognize if it s...

Page 9: ...an see it from its code as it containes the heater W value in the description e g MEVA7EJ FAN COIL EVA 7 DRY PAN J RES 1300W has a 1 3kW heater 2 3 Main menu The main menu is accessible through the ma...

Page 10: ...nit works only in heat mode SCHEDULE In this mode the system will work based on the scheduled of the selected program see Chapter 2 4 for more LANGUAGE DATE TIME This screen allows modifying language...

Page 11: ...rtup see 2 2 Initial settings at first start up Modbus address from this screen you can change the Modbus address of the electrical board only for fancoils with MV8 control Celsius Farenheit from this...

Page 12: ...o to the Main Menu MAIN MENU MODE SCHEDULE From the main Scheduler screen you can Turn the Scheduler ON or OFF or access one over the 6 programs to select them check how they are configured or modify...

Page 13: ...grammed correctly then the change over probe maybe faulty ERROR 2 Communication timeout ERROR 3 External alarm ERROR 4 Clean filter alarm This is a warning that comes every 2500 running hours and it s...