6
BX 2E-15E
User and installation instructions
Use
This appliance can be used by children aged from 8 years
and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction con-
cering use of the appliance in a safe way and understand
the hazards involved, Childen shall not play with the
appliance. Cleaning and user maintenance shall not be
made by children without supervision.
Children aged from 3 years and less than 8 years shall
only switch on/off the appliance provided that it has
been placed or installed in its intended normal operating
position and they have been given supervision or instruc-
tion concerning use of the appliance in a safe way and
understand the hazards involved. Children aged from 3
years and less than 8 years shall not plug in, regulate and
clean the appliance or perform user maintenance.
CAUTION
– Some parts of this product can become
very hot and cause burns. Particular attention has to be
given where children and vulnerable people are present.
The electric fan heater is intended for space heating in
various premises. It is movable, but can also be perma-
nently installed. The electric fan heater is approved for
use in humid and wet areas, and is employed on buil-
ding sites, in stores and shops, and in the home. The
fan heater has been subjected to electrical safety testing
and EMC-testing by SEMKO. The fan heater is CE
marked. Degree of protection: IP X4 (corresponds to
splash-proof)
Safety
• Don’t use this heater in the immediate vicinity of a
shower, bath or swimming pool.
• Don’t cover the heater since it could then overheat and
could cause a fire (see also Figure A).
GB
Kiinteä asennus
Kiinteässä asennuksessa on lämmitin asennettava vähin-
tään 1800 mm lattian yläpuolelle. Pienin etäisyys katon
ja seinän välillä selviää kuvasta B. Kiinnitä lämpöpu-
hallin seinään ruuveilla konsolin kehdesta reiästä ja
varmista, että puhallin pysyy varmasti kiinni. Lämmit
-
timen moottorisuojakytkimen on oltava kärkiväliltään
vähintään 3 mm. Tarkista puhaltimen datakilvestä, sekä
kannessa olevasta kytkentäkaaviosta, että asennus suori-
tetaan oikealla tavalla. Valtuutettu sähköasentaja suorit-
taa asennuksen määräysten mukaisesti.
• Some of the heater surfaces become hot when the hea
-
ter is in operation.
• Locate the heater so that any combustible material will
not be ignited.
• Don’t locate the heater immediately below a permanent
wall-mounted power outlet.
• If permanently installed in a bathroom or shower
room, make sure that the heater is installed so that
the person using the bath or shower will not be able to
touch it.
Operation
Thermostatically controlled fan motor
The fan motor will stop when the thermostat has swit-
ched off the heater.
1. Fan (BX 9AE Low speed)
2. Fan + 1/2 output (BX 5ER - 2/3 output)
3. Fan + 1/1 output
Continuous operation
The fan motor runs continuously regardless of the ther-
mostat setting.
4. Fan (BX 9AE High speed)
5. Fan + 1/2 output (BX 5ER - 2/3 output)
6. Fan + 1/1 output
Thermostat, 0 – 35°C
7. The thermostats in BX 2E and BX 3E have one
output stage, while other models have two output
stages.
A
1
2
3
4
5
6
7
Summary of Contents for BX 2E-15E
Page 15: ...15 BX 2E 15E 1800 3...