PROBLEM
PROBABLE CAUSE
SOLUTION
On giving a command
with the remote
control or with the
key-switch, the barrier
doesn’t open or the
motor doesn’t start
230 volt mains voltage
absent
Check master switch
Emergency STOP
present
Check for any STOP
selectors or commands.
If not used, check jump-
er on STOP contact in-
put on the control board
Fuse blown
Replace with one of
same value.
Power cable of motor or
motors not
connected or faulty.
Connect the cable to
appropriate
terminal or replace.
The photocell is not
functioning or the
beam is interrupted
Check the connection,
remove any
obstacle across the
beam
On giving a command
with the remote control,
the barrier doesn’t open
but
works with the key
command
The remote control has
not been
memorised or the bat-
tery is flat
Carry out the remote
control learning
procedure on the radio
receiver or replace the
battery with a new one..
The barrier starts, but
stops immediately
The force of the motor or
motors is insufficient
Modify the value with the
FORCE trimmer on the
control unit
N.B. - If the problem persists, contact your Retailer or the nearest Service
Centre
TROUBLESHOOTING
Summary of Contents for BEV 2
Page 1: ......