11/14
1-9
3
6
0,5...20 mm
8
2
1
1,5...3 mm
7
9
GB
INSTALLATION INSTRUCTIONS: Viewline 110 mm
TU00-0758-5307102
Technische Änderungen vorbehalten - Technical details subject to change
TU00-0758-5307102
GPS Speedometer
•
Do not drill holes or ports in load-bearing or stabilizing stays or tie bars!
•
Note the necessary clearance behind the drill hole or port at the installation location. Required
mounting depth: 65 mm.
•
Drill small ports; enlarge and complete them, if necessary using taper milling tools, saber saw,
keyhole saw or file. Debur edges. Follow the safety instructions of the tool manufacturer.
Conventional assembly. (Instrument is put into the drill
hole from the front).
The panel width may be within a range of 0.5 to 20
mm. The drill hole must have a diameter of 111 mm.
dia. 111 mm
dia. 105,4
mm
Place the flush mount seal A2C53215642 on the
instrument glass.
Put the instrument into the drill hole from the back.
Adjust the instrument so that the gauge is level and
fasten it to the stud bolts on the rear side of the panel
using the flush mount fixing bracket A2C59510864.
If the instrument will be mounted flush (i.e., from the
back so that the instrument glass and the panel form
one plane), the bezel must be removed. Press the
instrument glass with both thumbs while at the same
time pressing the bezel forward from the instrument
with both index fingers. Note the use of a tool in the
adjacent figure.
Flush assembly.
The recommended panel thickness is 1.5 to 3 mm.
The drill hole must have a diameter of 105.4 mm.
Ensure that the installation location is level and has no
sharp edges.
• Do not drill holes or ports in load-bearing or stabilizing stays or tie bars!
• Note the necessary clearance behind the drill hole or port at the installation location. Required mounting depth:
65 mm.
• Drill small ports; enlarge and complete them, if necessary using taper milling tools, saber saw, keyhole saw
or file. Debur edges. Follow the safety instructions of the tool manufacturer.