11/14

1-9

3

6

0,5...20 mm

8

2

1

1,5...3 mm

7

9

GB

INSTALLATION INSTRUCTIONS: Viewline 110 mm

TU00-0758-5307102

Technische Änderungen vorbehalten  -  Technical details subject to change

TU00-0758-5307102

GPS Speedometer

  Do not drill holes or ports in load-bearing or stabilizing stays or tie bars! 

  Note the necessary clearance behind the drill hole or port at the installation location. Required 

 mounting depth: 65 mm. 

  Drill small ports; enlarge and complete them, if necessary using taper milling tools, saber saw,  

keyhole saw or file. Debur edges. Follow the safety instructions of the tool manufacturer. 

Conventional assembly. (Instrument is put into the drill 

hole from the front). 

The panel width may be within a range of 0.5 to 20 

mm. The drill hole must have a diameter of 111 mm.  

dia. 111 mm

dia. 105,4 

mm

Place the flush mount seal A2C53215642 on the 

instrument glass. 

Put the instrument into the drill hole from the back.  

Adjust the instrument so that the gauge is level and 

fasten it to the stud bolts on the rear side of the panel 

using the flush mount fixing bracket A2C59510864.

If the instrument will be mounted flush (i.e., from the 

back so that the instrument glass and the panel form 

one plane), the bezel must be removed. Press the 

instrument glass with both thumbs while at the same 

time pressing the bezel forward from the instrument 

with both index fingers. Note the use of a tool in the 

adjacent figure.

Flush assembly.

The recommended panel thickness is 1.5 to 3 mm. 

The drill hole must have a diameter of 105.4 mm. 

Ensure that the installation location is level and has no 

sharp edges. 

•  Do not drill holes or ports in load-bearing or stabilizing stays or tie bars!
•  Note the necessary clearance behind the drill hole or port at the installation location. Required mounting depth: 

65 mm. 

•  Drill small ports; enlarge and complete them, if necessary using taper milling tools, saber saw, keyhole saw  

or file. Debur edges. Follow the safety instructions of the tool manufacturer.

Summary of Contents for Viewline 110 mm

Page 1: ...es or ports in load bearing or stabilizing stays or tie bars When working underneath the vehicle secure it according to the specifications from the vehicle manufacturer Note the necessary clearance behind the drill hole or port at the installation location Required mounting depth 65 mm Drill small ports enlarge and complete them if necessary using taper milling tools saber saws keyhole saws or fil...

Page 2: ...ion key If necessary remove the main circuit switch Disconnect the negative terminal on the battery Make sure the battery cannot unintentionally restart Before taking any action disconnect the negative terminal on the battery otherwise you risk a short circuit If the vehicle is supplied by auxiliary batteries you must also disconnect the negative terminals on these batteries Short circuits can cau...

Page 3: ...o the drill hole from the back Adjust the instrument so that the gauge is level and fasten it to the stud bolts on the rear side of the panel using the flush mount fixing bracket A2C59510864 If the instrument will be mounted flush i e from the back so that the instrument glass and the panel form one plane the bezel must be removed Press the instrument glass with both thumbs while at the same time ...

Page 4: ...e 2 PGN 129026 COG SOG rapid update 3 PGN 129033 Time Date time only 4 PGN 060928 ISO Address Claim NMEA 2000 compatible The instrument will provide the following information The signal lines are not electronically isolated from power lines Connector set 8 pin A2C59510850 Use the following connector cable to connect the instrument Connector cable A2C95822600 The connector cable is designed for a c...

Page 5: ... exposed stranded wires to prevent short circuits Caution Risk of short circuit if junctions are faulty or cables are damaged Short circuits in the vehicle network can cause fires battery explo sions and damages to other electronic systems Consequently all power supply cable connections must be provided with weldable connectors and sufficiently insulated Ensure ground connections are sound Faulty ...

Page 6: ...heir input values and must be reprogrammed GB INSTALLATION INSTRUCTIONS Viewline 110 mm TU00 0758 5307102 Technische Änderungen vorbehalten Technical details subject to change TU00 0758 5307102 GPS Speedometer Align the instrument and hand tighten the fastening nut Ensure that the nut is not tightened with a torque greater than 400 Ncm Make sure the seal lays flat between the panel and the bezel I...

Page 7: ...d the mode button 2 sec By briefly pressing the mode button to switch between 24h and 12h AM PM clock format Press and hold the mode button 2 sec to save the settings Press the mode button to display the course over ground screen Press the mode button briefly 2 sec to switch to the next screen The next screen displays the UTC time Press the mode button briefly 2 sec to switch to the next screen Th...

Page 8: ...ds above 2 6 kmh 1 6 mph 1 4 knots Maximum value 999 9 km mi nm 999 9 Trip separator blinking 1Hz Trip distance is available trip distance is being counted Trip separator permanently on Trip distance is not being counted speed below threshold or no fix 3 5 Warning light Function Warning light on continuously for 1 second Battery Pin 1 and ignition Pin 4 are switched on Warning light permanently on...

Page 9: ...embly mounting set A2C59510854 Flush mount fixing bracket A2C59510864 Flush mount seal A2C53215642 Push button A2C59512684 Fastening nut A2C53238881 Protective connector cap 8 pin A2C53324664 Protective connector cap 14 pin A2C53324671 Black White Chrome Round A2C53210749 A2C53210760 A2C53210761 Flat A2C53210745 A2C53210746 A2C53210747 Triangular A2C53210763 A2C53210764 A2C53210765 3 6 Resetting t...

Reviews: