Accessories / Spare parts

Bush contacts 0.25 – 0.5 mm²   A2C59510846

Bush housing, 8-pin  

A2C59510847

Hand pliers  

Tyco No. 539635-1

Tool for hand pliers  

Tyco No. 539682-2

Single contacts 0.14 – 0.22 mm²   Tyco No. 1355718-1

Single contacts 0.5 – 0.75 mm²   Tyco No. 963729-1

Strip 0.14 – 0.22 mm²  

Tyco No. 1355717-1

Strip 0.25 – 0.5 mm²  

Tyco No. 928999-1

Bezel

Strip 0.5 – 0.75 mm²  

Tyco No. 963715-1

Bracket assembly mounting set   A2C59510854 

Flush mount fixing bracket  

A2C59510864

Flush mount seal  

A2C53215642

Push button 

A2C59512684

Fastening nut 

A2C53238881

Protective connector cap, 8 pin  A2C53324664

Protective connector cap, 14 pin  A2C53324671

Black

White

Chrome

Round

A2C53210749

A2C53210760

A2C53210761

Flat

A2C53210745

A2C53210746

A2C53210747

Triangular

A2C53210763

A2C53210764

A2C53210765

3.6 Resetting the day counter

1. Connect pin 1 to terminal 30 (Bat. +) 

2. Switch on the ignition (Term. 15, pin 4)

Press the mode button repeatedly until the trip distance is displayed.

Press and hold the mode button for longer (>2 sec.).

Trip is now deleted.

 3.7 Resetting the trip hour

1. Connect pin 1 to terminal 30 (Bat. +) 

2. Switch on the ignition (Term. 15, pin 4)

Press the mode button repeatedly until the trip time is displayed.

Press and hold the mode button for longer (>2 sec.).

Trip is now deleted.

Summary of Contents for Viewline 110 mm

Page 1: ...es or ports in load bearing or stabilizing stays or tie bars When working underneath the vehicle secure it according to the specifications from the vehicle manufacturer Note the necessary clearance behind the drill hole or port at the installation location Required mounting depth 65 mm Drill small ports enlarge and complete them if necessary using taper milling tools saber saws keyhole saws or fil...

Page 2: ...ion key If necessary remove the main circuit switch Disconnect the negative terminal on the battery Make sure the battery cannot unintentionally restart Before taking any action disconnect the negative terminal on the battery otherwise you risk a short circuit If the vehicle is supplied by auxiliary batteries you must also disconnect the negative terminals on these batteries Short circuits can cau...

Page 3: ...o the drill hole from the back Adjust the instrument so that the gauge is level and fasten it to the stud bolts on the rear side of the panel using the flush mount fixing bracket A2C59510864 If the instrument will be mounted flush i e from the back so that the instrument glass and the panel form one plane the bezel must be removed Press the instrument glass with both thumbs while at the same time ...

Page 4: ...e 2 PGN 129026 COG SOG rapid update 3 PGN 129033 Time Date time only 4 PGN 060928 ISO Address Claim NMEA 2000 compatible The instrument will provide the following information The signal lines are not electronically isolated from power lines Connector set 8 pin A2C59510850 Use the following connector cable to connect the instrument Connector cable A2C95822600 The connector cable is designed for a c...

Page 5: ... exposed stranded wires to prevent short circuits Caution Risk of short circuit if junctions are faulty or cables are damaged Short circuits in the vehicle network can cause fires battery explo sions and damages to other electronic systems Consequently all power supply cable connections must be provided with weldable connectors and sufficiently insulated Ensure ground connections are sound Faulty ...

Page 6: ...heir input values and must be reprogrammed GB INSTALLATION INSTRUCTIONS Viewline 110 mm TU00 0758 5307102 Technische Änderungen vorbehalten Technical details subject to change TU00 0758 5307102 GPS Speedometer Align the instrument and hand tighten the fastening nut Ensure that the nut is not tightened with a torque greater than 400 Ncm Make sure the seal lays flat between the panel and the bezel I...

Page 7: ...d the mode button 2 sec By briefly pressing the mode button to switch between 24h and 12h AM PM clock format Press and hold the mode button 2 sec to save the settings Press the mode button to display the course over ground screen Press the mode button briefly 2 sec to switch to the next screen The next screen displays the UTC time Press the mode button briefly 2 sec to switch to the next screen Th...

Page 8: ...ds above 2 6 kmh 1 6 mph 1 4 knots Maximum value 999 9 km mi nm 999 9 Trip separator blinking 1Hz Trip distance is available trip distance is being counted Trip separator permanently on Trip distance is not being counted speed below threshold or no fix 3 5 Warning light Function Warning light on continuously for 1 second Battery Pin 1 and ignition Pin 4 are switched on Warning light permanently on...

Page 9: ...embly mounting set A2C59510854 Flush mount fixing bracket A2C59510864 Flush mount seal A2C53215642 Push button A2C59512684 Fastening nut A2C53238881 Protective connector cap 8 pin A2C53324664 Protective connector cap 14 pin A2C53324671 Black White Chrome Round A2C53210749 A2C53210760 A2C53210761 Flat A2C53210745 A2C53210746 A2C53210747 Triangular A2C53210763 A2C53210764 A2C53210765 3 6 Resetting t...

Reviews: