The steps involved in measuring and testing
The steps involved in measuring and testing SmarTach
®
6.3.2
SmarTach
®
calibration
During initial calibration or periodic inspection of the
SmarTach
®
,
you must carry out the steps in the exact
order in which they are described below!
◄
Important
Step 1
Programming the installation data
•
Confirm or change (where necessary) the legal
parameters.
•
Confirm or change (where necessary) the non-legal
parameters, e. g. device-specific and vehicle-specific
parameters.
See
Chapter 10
on
Page 56
Remark:
The legal parameters are first saved in the test device. The
non-legal parameters are immediately transferred as
individual values (programmed).
Step 2
Determination of the characteristic coefficient imp/km
(W value):
Measuring on the road or on the rolling road.
Remark:
The determined values are first saved in the test device.
Step 3
Calibration of the SmarTach
®
using the
key:
The CTC II carries out the following steps:
•
Adjustment of the K value
•
Transfer (programming) of the legal parameters
•
Pairing with the KITAS (updating of the KITAS data); see
Chapter 9
"
" on
Page 55
.
Remark:
Calibration lasts around 150 seconds.