33
FUNCTIONS / BASIC SETTINGS
The following instruments can be connected to the output channels:
-
2 rev counters
-
6 gauges (impedance) e.g. temperature pressure, fuel level
-
2 gauges (4-20mA) e.g. water level
The basic settings
The basic settings required for correct operation can be established by
programming the BAIe with the aid of PC software which is available as
an option.
The programming process is described in detail in the documentation for
the software.
The works settings of the BAIe are as listed below:
MID = 112 (BAIe address)
Plug 1:
Pin No. Designation
MID
PID
Remarks
1.5
Alarm silent
112
254
Alarm silent
Plug 2:
Pin No. Designation
MID
PID
Gauge type
2.1
Temperature 1
120
105
Temp. 120°C / 250°F
2.2
Temperature 2
120
176
Temp. 150°C / 300°F
2.3
Pressure 1
120
102
Pressure 2 Bar / 48 Psi
2.4
Pressure 2
121
100
Pressure 10 Bar / 150 Psi
2.5
120
168
Any (impedance)
2.6
Fuel level
120
96
Level gauge (lever)
2.7
Fresh water level
120
38
Water level (4...20mA)
2.8
1
254
Any (4...20mA)
2.9
Rev counter 1
120
190
4000 rpm / 250Hz
2.10
Rev counter 2
121
190
4000 rpm / 250Hz
If terminal 1.5 is connected to +U
Batt
any activated alarms are deactivated
and the BAIe sends an Alarm silent command to the bus.