PROBA 5
Doc.nr: 170366
Version: 1.1
2.1.4.7.2 Specific measurements
Fig. 24
Specific measurement status
To reach the desired temperature inside the product it is possible that the temperature of the cell
changes to extreme values. To avoid this it is possible to limit the temperature inside the cell.
The Air Limit sensor contains two limit values to limit the temperature of the cell.
Click with left mouse button at value and enter new limit values.
Fig. 25
Change limit values for temperature
(De)activate
sensors & zones
Use right mouse button to
de-activate sensors and zones
individually. De-activated items
are greyed out.
activated
de-activated
Product control sensor
Sensor number
Graphical presentation
Measured value
Air control sensor
Air info sensor
Reversed air control sensor
Reversed air info sensor
Air limit sensor
Coolant sensor
Product info sensor