MC2-FC mode FC
Document no.:200064
Version: 1.5
Page 26 of 44
Nr
Description
Range
Unit
Default
Network
P 801
Network number (define unique number for every controller
included in the network)
1..31
-
1
P 802
Store group number (0 = Not active)
Controllers in store phase with the same store group numbers in
the same sub-network will start cooling at the same time
0..31
-
0
P 803
Cooling capacity of this cell
0.0..100
kW
0.0
P 804
Maximum cooling capacity to be requested in cool phase
(in sub-network)
1..500
kW
500
P 805
Set point linked to controller in the same sub-network
with network number (0 = Not linked)
0..31
-
0
P 806
Cool group number: (0 = Not active)
Controllers in cool phase with the same cool group numbers in
the same sub-network will start cooling at the same time
0..31
-
0
P 807
Sub-network number
Only controllers with the same sub-network number work
together in a network (multiple masters on the same network
can be realised in this way.)
0..31
-
0
Other
P 901
Cell may be used as standby cell if hotgas is requested by another
cell
0=No
1=Yes
0..1
-
0
P 902
Maximum door contact time
0..999
min
5
P 904
Access code (0000 = Not active)
0000..9999
-
0000
P 907
Language control panel
0 = Dutch
1 = English
2 = German
0..2
-
1
P 908
Standard cell page control panel
1 = Cell page 1
2 = Cell page 2 (large font control temperature)
1..2
-
1