32
E
N
G
Causes
Solutions
The machine does not
dispense hot water.
Steam switch in position “OFF”.
No water in the tank.
It is possible that the delivery
ducts are clogged with
limescale.
Set the switch to “ON”.
Check that the water level in the
tank is correct and in case fill
with fresh natural water.
Call the technician to perform
the descaling.
The machine does not
produce steam.
Steam switch in position “OFF”.
Steam boiler not in temperature.
No water in the tank.
Holes in the spout of the steam
nozzle clogged.
It is possible that the delivery
ducts are clogged with
limescale.
Set the switch to “ON”.
Wait until the temperature is
reached, indicated on the gauge
of the steam pressure (1 ÷ 1,2
bar).
Check that the water level in the
tank is correct and in case fill
with fresh natural water.
Clean, with a pin, any deposits
formed in the hole of the spout.
Call the technician to perform
the descaling.
NEWManuale_DomobarJunior2B_Rev0_01-2016_5lingue.indd 32
17/03/16 17:21
Summary of Contents for JUNIOR 2B
Page 38: ...NOTE NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 36 17 03 16 17 21 ...
Page 74: ...NOTE NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 36 17 03 16 17 21 ...
Page 108: ...34 F R A 11 CÂBLAGE NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 34 17 03 16 17 22 ...
Page 110: ...NOTE NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 36 17 03 16 17 22 ...
Page 146: ...NOTE NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 36 17 03 16 17 22 ...
Page 180: ...34 E S P 11 CABLEADO NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 34 17 03 16 17 22 ...
Page 182: ...NOTE NEWManuale_DomobarJunior2B_Rev0_01 2016_5lingue indd 36 17 03 16 17 22 ...
Page 183: ...Retro_DomobarBase_ed2_01 2016_5lingue_LAYOUT indd 1 09 03 16 16 53 ...