10
E
N
G
Noise
< 70 db
Temperature of operation
+5° to +30°C
Storage temperature
+5° to +40°C
Net weight
33 kg
2.3,
SAFETY.
·
Panels of protection of the inner parts fastened with screws.
·
Water level sensor.
When the water reaches the minimum level (1,5 cm from the bottom) automatically all the
functions of the machine are disabled, the line led remains illuminated indicating voltage on.
Turn off the machine by placing the main switch on “OFF” and fill the water tank as described
in the relevant paragraph.
SAFETY THERMOSTAT
·
It turns on when the temperature in the boiler reaches 150°C by disconnecting the voltage
to the resistance in order to prevent the burn.